Golem shot: 4284

2010-12-06 - 162652

Basic parameters:
  • Chamber pressure pchamber : 3.06->27.77 mPa (request: 20 mPa)
  • Chamber temperature: 8 grad C
  • CBt capacitors (23 mF) charged to: 400 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 1790 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.34 over 5.68 to 15.02 [ms]
  • Mean toroidal magnetic field Bt: 0.091 T
  • Mean plasma current: 1.7 kA
  • Mean Uloop: 9.0 V
  • Break down voltage: 11.9 V
  • Plasma total charge: 9.6 C
  • Ohmic heating power: 15.3 kW
  • Q edge: 4.8
  • Central electron temperature: 29.6 eV

MirnovCoils


Bolometry

Diagnostics configuration

Thanks to the specific help and