Golem shot: 4364

2010-12-22 - 160115

Basic parameters:
  • Chamber pressure pchamber : 1.94->20.12 mPa (request: 20 mPa)
  • Chamber temperature: 9 grad C
  • CBt capacitors (23 mF) charged to: 500 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 4495 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 10.45 over 5.88 to 16.33 [ms]
  • Mean toroidal magnetic field Bt: 0.129 T
  • Mean plasma current: 1.2 kA
  • Mean Uloop: 7.5 V
  • Break down voltage: 9.9 V
  • Plasma total charge: 7.1 C
  • Ohmic heating power: 9.0 kW
  • Q edge: 9.7
  • Central electron temperature: 26.5 eV

MirnovCoils

Diagnostics configuration

Thanks to the specific help and