Golem shot: 4368

2010-12-22 - 163957

Basic parameters:
  • Chamber pressure pchamber : 1.87->20.58 mPa (request: 20 mPa)
  • Chamber temperature: 12 grad C
  • CBt capacitors (23 mF) charged to: 1200 V
  • CBD capacitors (3.6 mF) charged to: 200 V, triggered 2,5 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 6852 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 7.68 over 9.57 to 17.25 [ms]
  • Mean toroidal magnetic field Bt: 0.308 T
  • Mean plasma current: 1.4 kA
  • Mean Uloop: 7.9 V
  • Break down voltage: 10.7 V
  • Plasma total charge: 13.0 C
  • Ohmic heating power: 11.1 kW
  • Q edge: 19.9
  • Central electron temperature: 28.3 eV

MirnovCoils

Diagnostics configuration

Thanks to the specific help and