Golem shot: 4370

2010-12-22 - 165830

Basic parameters:
  • Chamber pressure pchamber : 1.81->20.35 mPa (request: 20 mPa)
  • Chamber temperature: 9 grad C
  • CBt capacitors (23 mF) charged to: 1200 V
  • CBD capacitors (3.6 mF) charged to: 200 V, triggered 2,5 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 130 V, triggered 10,5 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 7967 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 7.67 over 10.3 to 17.97 [ms]
  • Mean toroidal magnetic field Bt: 0.297 T
  • Mean plasma current: 1.5 kA
  • Mean Uloop: 7.9 V
  • Break down voltage: 10.1 V
  • Plasma total charge: 15.3 C
  • Ohmic heating power: 11.9 kW
  • Q edge: 17.9
  • Central electron temperature: 29.7 eV

MirnovCoils

Diagnostics configuration

Thanks to the specific help and