Golem shot: 4373

2011-01-05 - 130232

Basic parameters:
  • Chamber pressure pchamber : 1.84->20.35 mPa (request: 20 mPa)
  • Chamber temperature: 9 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 3522 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.4 over 6.37 to 15.77 [ms]
  • Mean toroidal magnetic field Bt: 0.144 T
  • Mean plasma current: 1.3 kA
  • Mean Uloop: 10.1 V
  • Break down voltage: 11.7 V
  • Plasma total charge: 8.0 C
  • Ohmic heating power: 13.1 kW
  • Q edge: 10.0
  • Central electron temperature: 22.9 eV

MirnovCoils

Diagnostics configuration

Thanks to the specific help and