Golem shot: 4380

2011-01-06 - 132623

Basic parameters:
  • Chamber pressure pchamber : 1.69->20.90 mPa (request: 20 mPa)
  • Chamber temperature: 9 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 14520 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.47 over 6.25 to 15.72 [ms]
  • Mean toroidal magnetic field Bt: 0.149 T
  • Mean plasma current: 1.2 kA
  • Mean Uloop: 10.2 V
  • Break down voltage: 12.0 V
  • Plasma total charge: 7.6 C
  • Ohmic heating power: 12.2 kW
  • Q edge: 11.2
  • Central electron temperature: 21.6 eV

MirnovCoils

Diagnostics configuration

Thanks to the specific help and