Golem shot: 4397

2011-01-07 - 122330

Basic parameters:
  • Chamber pressure pchamber : 1.93->22.74 mPa (request: 20 mPa)
  • Chamber temperature: 8 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 4812 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.06 over 8.08 to 16.14 [ms]
  • Mean toroidal magnetic field Bt: 0.166 T
  • Mean plasma current: 2.3 kA
  • Mean Uloop: -0.5 V
  • Break down voltage: -1.9 V
  • Plasma total charge: 18.4 C
  • Ohmic heating power: 1.1 kW
  • Q edge: 6.5
  • Central electron temperature: 248.4 eV

MirnovCoils


Bolometry

Diagnostics configuration

Thanks to the specific help and