Golem shot: 4398

2011-01-07 - 122556

Basic parameters:
  • Chamber pressure pchamber : 2.00->19.36 mPa (request: 20 mPa)
  • Chamber temperature: 11 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 4955 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.41 over 6.77 to 16.18 [ms]
  • Mean toroidal magnetic field Bt: 0.148 T
  • Mean plasma current: 1.4 kA
  • Mean Uloop: 9.9 V
  • Break down voltage: 11.9 V
  • Plasma total charge: 9.8 C
  • Ohmic heating power: 13.9 kW
  • Q edge: 9.5
  • Central electron temperature: 24.4 eV

MirnovCoils


Bolometry

Diagnostics configuration

Thanks to the specific help and