Golem shot: 4401

2011-01-07 - 123521

Basic parameters:
  • Chamber pressure pchamber : 1.97->19.96 mPa (request: 20 mPa)
  • Chamber temperature: 11 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 5520 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.43 over 6.95 to 16.38 [ms]
  • Mean toroidal magnetic field Bt: 0.140 T
  • Mean plasma current: 1.2 kA
  • Mean Uloop: 9.6 V
  • Break down voltage: 11.9 V
  • Plasma total charge: 8.2 C
  • Ohmic heating power: 11.5 kW
  • Q edge: 10.5
  • Central electron temperature: 22.4 eV

MirnovCoils


Bolometry

Diagnostics configuration

Thanks to the specific help and