Golem shot: 4412

2011-01-07 - 152122

Basic parameters:
  • Chamber pressure pchamber : 1.78->21.39 mPa (request: 20 mPa)
  • Chamber temperature: 12 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 15482 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.43 over 7.51 to 16.94 [ms]
  • Mean toroidal magnetic field Bt: 0.150 T
  • Mean plasma current: 1.7 kA
  • Mean Uloop: 9.4 V
  • Break down voltage: 11.8 V
  • Plasma total charge: 12.6 C
  • Ohmic heating power: 16.0 kW
  • Q edge: 8.0
  • Central electron temperature: 28.7 eV

MirnovCoils


Bolometry

Diagnostics configuration

Thanks to the specific help and