Golem shot: 4415

2011-01-07 - 154528

Basic parameters:
  • Chamber pressure pchamber : 1.72->20.98 mPa (request: 20 mPa)
  • Chamber temperature: 12 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 16928 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.39 over 7.68 to 17.07 [ms]
  • Mean toroidal magnetic field Bt: 0.151 T
  • Mean plasma current: 1.7 kA
  • Mean Uloop: 9.4 V
  • Break down voltage: 11.6 V
  • Plasma total charge: 13.3 C
  • Ohmic heating power: 16.0 kW
  • Q edge: 8.0
  • Central electron temperature: 28.7 eV

MirnovCoils


Bolometry

Diagnostics configuration

Thanks to the specific help and