Golem shot: 4416

2011-01-07 - 155007

Basic parameters:
  • Chamber pressure pchamber : 1.74->20.82 mPa (request: 20 mPa)
  • Chamber temperature: 12 grad C
  • CBt capacitors (23 mF) charged to: 1200 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 17233 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.05 over 8.68 to 17.73 [ms]
  • Mean toroidal magnetic field Bt: 0.315 T
  • Mean plasma current: 2.1 kA
  • Mean Uloop: 11.4 V
  • Break down voltage: 10.0 V
  • Plasma total charge: 18.0 C
  • Ohmic heating power: 23.9 kW
  • Q edge: 13.5
  • Central electron temperature: 29.1 eV

MirnovCoils


Bolometry

Diagnostics configuration

Thanks to the specific help and