Golem shot: 4434

2011-01-27 - 114857

Basic parameters:
  • Chamber pressure pchamber : 2.40->20.74 mPa (request: 20 mPa)
  • Chamber temperature: 12 grad C
  • CBt capacitors (23 mF) charged to: 1100 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 1078 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.49 over 8.2 to 16.69 [ms]
  • Mean toroidal magnetic field Bt: 0.286 T
  • Mean plasma current: 1.5 kA
  • Mean Uloop: 7.8 V
  • Break down voltage: 10.8 V
  • Plasma total charge: 12.0 C
  • Ohmic heating power: 11.7 kW
  • Q edge: 17.2
  • Central electron temperature: 29.9 eV

MirnovCoils

Diagnostics configuration

Thanks to the specific help and