The session survey for the 24-04-25

(psql command: SELECT shot_no,"X_discharge_command" FROM operation.discharges WHERE session_id LIKE "44638 %" ORDER BY shot_no ASC LIMIT 200)

Mission="SFP"

Staff="Students & Dirigent"

#44638 (24-04-25 16:25:26)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=23" --comment "Standard discharge"


























#44639 (24-04-25 16:28:51)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=21" --comment "Standard discharge"


























#44640 (24-04-25 16:39:28)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=1000,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=20" --comment "Skupina Alfa / prvni vyboj, prvni test "


























#44641 (24-04-25 16:53:35)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=600,t_cd=1200,O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=50,U_accel=80" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=20" --comment "Skupina Alfa / prvni vyboj, prvni test "


























#44642 (24-04-25 16:58:32)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=600,t_cd=1200,O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=50,U_accel=50" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=20" --comment "Skupina Gamma / prvni vyboj, prvni test "


























#44643 (24-04-25 17:03:50)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=500,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=20" --comment "Skupina Sigma / zkousime menit zpozdeni elektrickzch poli -- nejprve snizujeme na polovinu " --Skupina Sigma / zkousime menit zpozdeni elektrickzch poli nejprve snizujeme na polovinu


























#44644 (24-04-25 17:09:09)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=900,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=20" --comment "Skupina Alfa / Predchozi vyboj neprobehl, pokusime se snizit toroidalni pole "


























#44645 (24-04-25 17:17:12)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=750,t_Bt=0,O_Bt='CW',U_cd=650,t_cd=1500,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=18" --comment "Skupina Xi / Nizsi tlak, vetsi oneskoreni, vetsi elektricky "


























#44646 (24-04-25 17:22:04)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=600,t_cd=1200,O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=10,U_accel=0" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=20" --comment "Skupina Gamma / druhy vyboj, min ionizace "


























#44647 (24-04-25 17:26:06)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=250,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=20" --comment "Skupina Sigma, vyboj 2, zkousime menit zpozdeni elektrickych poli -- nyni snizujeme na ctvrtinu " --Skupina Sigma, vyboj 2, zkousime menit zpozdeni elektrickych poli nyni snizujeme na ctvrtinu


























#44648 (24-04-25 17:31:07)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=950,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=20" --comment "Skupina Alfa / Po uspesnem predchozim vyboji se pokusime najit mezni hodnotu toroidalniho pole, zvysujeme B na 950. "


























#44649 (24-04-25 18:12:54)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=2000,O_Bt='CW',U_cd=500,t_cd=3000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=20" --comment "Master discharge"


























#44650 (24-04-25 18:16:47)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=000,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=21" --comment "Master discharge"