Golem shot: 4502

2011-02-08 - 085708

Basic parameters:
  • Chamber pressure pchamber : 4.07->3.89 mPa (vacuum shot)
  • Chamber temperature: 0 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 741 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.69 over 6.45 to 16.14 [ms]
  • Mean toroidal magnetic field Bt: 0.150 T
  • Mean plasma current: 1.4 kA
  • Mean Uloop: 10.0 V
  • Break down voltage: 12.6 V
  • Plasma total charge: 8.9 C
  • Ohmic heating power: 14.0 kW
  • Q edge: 9.7
  • Central electron temperature: 24.2 eV

MirnovCoils

Diagnostics configuration

Thanks to the specific help and