Golem shot: 4511

2011-02-08 - 144823

Basic parameters:
  • Chamber pressure pchamber : 20.82->19.06 mPa (request: 20 mPa)
  • Chamber temperature: 0 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 6785 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.41 over 6.27 to 15.68 [ms]
  • Mean toroidal magnetic field Bt: 0.147 T
  • Mean plasma current: 1.1 kA
  • Mean Uloop: 10.2 V
  • Break down voltage: 11.8 V
  • Plasma total charge: 7.2 C
  • Ohmic heating power: 11.2 kW
  • Q edge: 12.1
  • Central electron temperature: 20.3 eV

MirnovCoils


FastCameraExilim

Diagnostics configuration

Thanks to the specific help and