Golem shot: 4512

2011-02-08 - 145715

Basic parameters:
  • Chamber pressure pchamber : 20.04->18.77 mPa (request: 15 mPa)
  • Chamber temperature: 0 grad C
  • CBt capacitors (23 mF) charged to: 1200 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 7344 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.36 over 8.71 to 18.07 [ms]
  • Mean toroidal magnetic field Bt: 0.315 T
  • Mean plasma current: 1.4 kA
  • Mean Uloop: 10.0 V
  • Break down voltage: 11.2 V
  • Plasma total charge: 12.1 C
  • Ohmic heating power: 14.0 kW
  • Q edge: 20.3
  • Central electron temperature: 24.2 eV

MirnovCoils


FastCameraExilim

Diagnostics configuration

Thanks to the specific help and