The session survey for the 24-06-13

(psql command: SELECT shot_no,"X_discharge_command" FROM operation.discharges WHERE session_id LIKE "45223 %" ORDER BY shot_no ASC LIMIT 200)

Mission="Full steam"

Staff="Stepan, Lukas, Marek, Petr & Dirigent"

#45223 (24-06-13 10:27:22)     ./Dirigent.sh --discharge --operation.discharge "style='sujb'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=21" --comment "Discharge dlouhodobe stability"




























#45224 (24-06-13 10:51:19)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,U_cd=450,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=22.0" --comment "NI read test 1"




























#45225 (24-06-13 11:00:46)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,U_cd=450,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=22.0" --comment "NI read test 2"




























#45226 (24-06-13 11:06:52)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,U_cd=500,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=21.0" --comment "NI read test 3"




























#45227 (24-06-13 11:13:20)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,U_cd=500,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=20.9" --comment "NI read test 4"