Golem shot: 4530

2011-02-15 - 092438

Basic parameters:
  • Chamber pressure pchamber : 3.77->3.66 mPa (vacuum shot)
  • Chamber temperature: 0 grad C
  • CBt capacitors (23 mF) charged to: 500 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 690 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.72 over 5.78 to 15.5 [ms]
  • Mean toroidal magnetic field Bt: 0.119 T
  • Mean plasma current: 1.3 kA
  • Mean Uloop: 9.9 V
  • Break down voltage: 12.4 V
  • Plasma total charge: 7.2 C
  • Ohmic heating power: 12.9 kW
  • Q edge: 8.3
  • Central electron temperature: 23.2 eV

MirnovCoils

Diagnostics configuration

Thanks to the specific help and