Golem shot: 4531

2011-02-15 - 092903

Basic parameters:
  • Chamber pressure pchamber : 3.22->3.11 mPa (vacuum shot)
  • Chamber temperature: 0 grad C
  • CBt capacitors (23 mF) charged to: 500 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 986 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 10.01 over 5.56 to 15.57 [ms]
  • Mean toroidal magnetic field Bt: 0.122 T
  • Mean plasma current: 1.3 kA
  • Mean Uloop: 9.7 V
  • Break down voltage: 13.0 V
  • Plasma total charge: 7.0 C
  • Ohmic heating power: 12.6 kW
  • Q edge: 8.5
  • Central electron temperature: 23.5 eV

MirnovCoils

Diagnostics configuration

Thanks to the specific help and