Golem shot: 4533

2011-02-15 - 093250

Basic parameters:
  • Chamber pressure pchamber : 3.00->2.93 mPa (vacuum shot)
  • Chamber temperature: 0 grad C
  • CBt capacitors (23 mF) charged to: 500 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 1181 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.64 over 6.24 to 15.88 [ms]
  • Mean toroidal magnetic field Bt: 0.120 T
  • Mean plasma current: 1.4 kA
  • Mean Uloop: 9.7 V
  • Break down voltage: 12.7 V
  • Plasma total charge: 8.6 C
  • Ohmic heating power: 13.6 kW
  • Q edge: 7.7
  • Central electron temperature: 24.7 eV

MirnovCoils

Diagnostics configuration

Thanks to the specific help and