Golem shot: 4534

2011-02-15 - 093522

Basic parameters:
  • Chamber pressure pchamber : 2.88->3.09 mPa (vacuum shot)
  • Chamber temperature: 0 grad C
  • CBt capacitors (23 mF) charged to: 500 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 1334 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.82 over 6.32 to 16.14 [ms]
  • Mean toroidal magnetic field Bt: 0.127 T
  • Mean plasma current: 1.0 kA
  • Mean Uloop: 7.8 V
  • Break down voltage: 11.1 V
  • Plasma total charge: 6.0 C
  • Ohmic heating power: 7.8 kW
  • Q edge: 11.5
  • Central electron temperature: 22.8 eV

MirnovCoils

Diagnostics configuration

Thanks to the specific help and