This notebook estimates several parameters of the plasma in the context of tokamak fusion physics. These parameters include but are not limited to the safety factor, the electron temperature, electron pressure, plasma volume and electron thermal energy and electron energy confinement time. Other more general plasma parameters are calculated as well.
The formulas and explanations are mostly based on the book [1] WESSON, John. Tokamaks. 3. ed. Oxford: Clarendon press, 2004. ISBN 9780198509226. and the reader is encouraged to consult it for details.
The accuracy of these parameters stronly depends on the availability of the plasma position and size reconstruction.
import os
import numpy as np
import pandas as pd
import matplotlib.pyplot as plt
from scipy import integrate, signal, interpolate, constants
import holoviews as hv
hv.extension('bokeh')
import hvplot.pandas
import requests
# 180221 Dirigent
destination='Results/'
os.makedirs(destination, exist_ok=True)
def print_and_save(phys_quant, value, format_str='%.3f'):
print(phys_quant+" = %.5f" % value)
with open(destination+phys_quant, 'w') as f:
f.write(format_str % value)
#update_db_current_shot(phys_quant,value)
def update_db_current_shot(field_name, value):
#os.system('psql -c "UPDATE shots SET '+field_name+'='+str(value)+' WHERE shot_no IN(SELECT max(shot_no) FROM shots)" -q -U golem golem_database')
subprocess.call(["psql -q -U golem golem_database --command='UPDATE shots SET \""+field_name+"\"="+str(value)+" WHERE shot_no IN(SELECT max(shot_no) FROM shots)'"],shell=True)
shot_no = 45361 # 33516 is a good test case
The following analysis makes sense only if a plasma was present in the discharge
def plasma_scalar(name):
r = requests.get(f'http://golem.fjfi.cvut.cz/shots/{shot_no}/Diagnostics/PlasmaDetection/Results/{name}')
return float(r.content)
t_plasma_start = plasma_scalar('t_plasma_start')
t_plasma_end = plasma_scalar('t_plasma_end')
if t_plasma_start == t_plasma_end:
raise RuntimeError('no plasma in this discharge, analysis cannot continue')
basic_diagn_signals = ['U_loop', 'Bt', 'Ip']
df = pd.concat([pd.read_csv(f'http://golem.fjfi.cvut.cz/shots/{shot_no}/Diagnostics/BasicDiagnostics/Results/{sig}.csv',
names=['time', sig], index_col=0) for sig in basic_diagn_signals], axis='columns')
df = df.loc[t_plasma_start:t_plasma_end] # time slice with plasma
#try:
# df_position = pd.read_csv(f'http://golem.fjfi.cvut.cz/shots/{shot_no}/Diagnostics/LimiterMirnovCoils/plasma_position.csv',
# index_col=0)
#except HTTPError:
df_position = None
using_plasma_position = df_position is not None
# TODO load from SQL
R0 = 0.4 # chamber center Major plasma radius [m]
a0 = 0.085 # maximum Minor radius - limiter [m]
If plasma position and size reconstruction is not available, the parameters of the chamber geometry are used for the minor and major plasma radii $a$ and $R$, respectivelly.
def interp_position2basic(name):
interp = interpolate.interp1d(df_position.index, df_position[name], bounds_error=False)
return interp(df.index) * 1e-3 # mm to m
if using_plasma_position:
df['R'] = R0 + interp_position2basic('r')
df['a'] = interp_position2basic('a')
else:
df['R'] = R0
df['a'] = a0
On any given closed flux surface in the plasma in the tokamak the magnetic field line performs $q$ transits in the toroidal angle $\phi$ per 1 one transit in the poloidal angle $\theta$. The stronger the toroidal magnetic field is, the more stable the plasma becomes against various instabilities, especially against the kink instability which can occur for $q<1$. For this reason $q$ is referred to as the safety factor.
In a simple tokamak with a circular cross-section (such as GOLEM) the poloidal magnetic field can be estimated at least at the very edge of the plasma from the total plasma current $I_p$ enclosed by the plasma column of minor radius $a$ and major radius $R$ as $$B_{\theta a} = \mu_0\frac{I_p}{2\pi a}$$
Typically, in a tokamak the toroidal magnetic field $B_\phi$ is several times stronger than the poloidal magnetic field $B_{\theta a}$ at the egde.
df['B_theta'] = constants.mu_0 * df['Ip'] * 1e3 / (2*np.pi*df['a']) # Ip is in [kA], B_theta will be in [T]
df[['Bt','B_theta']].hvplot(ylabel='B [T]', xlabel='time [ms]', grid=True, logy=True, ylim=(1e-4,None))
For a large aspect ratio tokamak (i.e. the inverse aspect ratio is small $\epsilon = \frac{a}{R} <<1$) such as GOLEM the safety factor at the edge on the last closed flux surface (LCFS) delimited by the limiter ring can be estimated as $$q_a=\frac{a B_\phi}{RB_\theta}$$
df['q_a'] = df['a'] * df['Bt'] / (df['R'] * df['B_theta'])
df['q_a'].hvplot(logy=True, grid=True)
WARNING:param.CurvePlot02008: Logarithmic axis range encountered value less than or equal to zero, please supply explicit lower-bound to override default of 764.208.
To obtain information on $q$ and $B_\theta$ deeper inside the plasma torus one must have knowledge of or assume a specific profile for the toroidal current density $j_\phi$. A common approximation for a tokamak such as GOLEM is a poloidally symmetric radial profile $$j_\phi(r) = j_0\left(1-\left(\frac{r}{a}\right)\right)^\nu$$ where $r$ is the radius with respect to the plasma center and $\nu$ a so called "peaking factor". A common choice is $\nu=1$ for a "parabolic" profile or $\nu=2$ for a more peaked profile (likely more realistic). With the average current density defined as $\langle j \rangle_a=\frac{I_p}{\pi a^2}$ the maximum current density $j_0$ can be estimated from the relation $\frac{j_0}{\langle j \rangle_a}=\nu+1$
nu = 2 # probably more realistic than parabolic
df['j_avg_a'] = df['Ip'] *1e3 / (np.pi*df['a']**2)
df['j_0'] = df['j_avg_a'] * (nu+1)
Under this assumption the safety factor in the plasma core ($r=0$) is reduced according to the relation $\frac{q_a}{q_0}=\nu+1$. which could result in the following profiles for the time when $q_a$ is the lowest (i.e. closest to an instability).
t_q_a_min = df['q_a'].idxmin()
df_q_a_min = df.loc[t_q_a_min]
print(f'min(q_a)={df_q_a_min["q_a"]:.2f} at t={t_q_a_min:.3f} ms')
min(q_a)=-125901.49 at t=14.325 ms
r = np.linspace(0, df_q_a_min['a'])
df_r = pd.DataFrame({
'j': df_q_a_min['j_0'] * (1-(r/df_q_a_min['a'])**2)**nu,
'B_theta': constants.mu_0 * df_q_a_min['j_0'] * df_q_a_min['a']**2 / (2*(nu+1)) * (1-(1-(r/df_q_a_min['a'])**2)**(nu+1))/r,
'q': 2*(nu+1)/(constants.mu_0 * df_q_a_min['j_0']) * (df_q_a_min['Bt']/df_q_a_min['R']) * (r/df_q_a_min['a'])**2 / (1-(1-(r/df_q_a_min['a'])**2)**(nu+1))
}, index=pd.Index(r, name='r')
)
<ipython-input-1-ec0bca19fa99>:4: RuntimeWarning: invalid value encountered in divide 'B_theta': constants.mu_0 * df_q_a_min['j_0'] * df_q_a_min['a']**2 / (2*(nu+1)) * (1-(1-(r/df_q_a_min['a'])**2)**(nu+1))/r, <ipython-input-1-ec0bca19fa99>:5: RuntimeWarning: invalid value encountered in divide 'q': 2*(nu+1)/(constants.mu_0 * df_q_a_min['j_0']) * (df_q_a_min['Bt']/df_q_a_min['R']) * (r/df_q_a_min['a'])**2 / (1-(1-(r/df_q_a_min['a'])**2)**(nu+1))
df_r.hvplot.line(subplots=True, shared_axes=False, width=300, grid=True)
The plasma is typically as conductive as copper, i.e. is a good conductor with a relatively low resitivity. However, whereas the resitivity of metals increases with temperature, the resitivity of a plasma decreases, because at higher timperatures collisions between particles become less frequent, leading to less resistance to their movement. While with higher particle density the number of collisions increases, the number of charge cariers also increases, so in the end the resistivity does not depend on density.
The simple, unmagnetized plasma resistivity derived by Spitzer $$\eta_s = 0.51 \frac{\sqrt{m_e} e^2 \ln \Lambda}{3 \epsilon_0^2 (2\pi k_B T_e)^\frac{3}{2}}$$ with the constants electron mass $m_e$, elementary charge $e$, vacuum permitivity $\epsilon_0$ and $k_B$ the Boltzmann constant. $\ln \Lambda$ is the so called Coulomb logarithm which has a weak dependence on density and temperature and for typical GOLEM plasmas can be held at $\ln \Lambda\sim 14$. The factor 0.51 comes from more precise calculations which show that the parallel resitivity $\eta_\|=\eta_s$ (along the magnetic field-line the resistivity is not affected by the field) is halved compared to the classical (analytical) perpendicular resitivity $\eta_\perp = 1.96 \eta_\|$ though in reality the perpendicular resitivity can be higher due to anomalous transport (turbelence, etc.). If one is interested in the electron temperature $T_e$ in the units of electron-volts (typically used in the field), the relation is $T_e \mathrm{[eV]}=\frac{k_B}{e}T_e\mathrm{[K]}$.
Additional corrections:
This results in $\eta_{measured}=\eta_s Z_{eff} (1-\sqrt{\epsilon})^{-2}$.
These considerations lead to the relation $$T_e \mathrm{[eV]}=\frac{1}{e2\pi}\left( \frac{1.96}{Z_{eff}} (1-\sqrt{\epsilon})^2 \eta_{measured}\frac{3 \epsilon_0^2}{\sqrt{m_e} e^2 \ln \Lambda} \right)^{-\frac{2}{3}}$$
def electron_temperature_Spitzer_eV(eta_measured, Z_eff=3, eps=0, coulomb_logarithm=14):
eta_s = eta_measured / Z_eff * (1-np.sqrt(eps))**2
term = 1.96 * eta_s * (3 * constants.epsilon_0**2 /
(np.sqrt(constants.m_e) * constants.elementary_charge**2 * coulomb_logarithm))
return term**(-2./3) / (constants.elementary_charge * 2*np.pi)
To estimate $\eta_{measured}$ one can use Ohm's law in the form $j_\phi = \sigma E_\phi$ with the plasma conductivity $\sigma=\frac{1}{\eta_{measured}}$. The toroidal electric field can be estimated from the loop voltage, but one must take into account inductive effects as well. Neglecting mutual inductances between e.g. the plasma and the chamber, the loop voltage induced in the plasma by the primary winding is "consumed" by the electric field and current inductance as $$U_{loop}= 2\pi R E_\phi + (L_i + L_e) \frac{dI_p}{dt}$$ where $L_i$ and $L_e$ are the internal and external plasma inductances, respectively. The external inductance of a closed toroidal current (assuming a uniform current density) is $L_e=\mu_0 R\ln\left(\frac{8R}{a}-\frac{7}{4}\right)$. The internal plasma inductance is usually parametrized as $L_i=\mu_0 R \frac{l_i}{2}$ where $l_i$ is the so called normalized internal inductance which depends on the $B_\theta$ (or rather current) profile. For the assumed current profile an accurate estimate is $l_i \approx \ln(1.65+0.89\nu)$.
l_i = np.log(1.65+0.89*nu)
df['L_p'] = constants.mu_0 * df['R'] * (np.log(8*df['R']/df['a']) - 7/4. + l_i/2)
dt = np.diff(df.index.values[:2]).item()
n_win = int(0.5 / dt) # use a window of 0.5 ms
if n_win % 2 == 0:
n_win += 1 # window must be odd
# needs SI units: convert current in kA -> A, time step in ms->s
df['dIp_dt'] = signal.savgol_filter(df['Ip']*1e3, n_win, 3, 1, delta=dt*1e-3) # 1. derivative of an order 3 polynomial lsq SG-filter
df['E_phi_naive'] = df['U_loop'] / (2*np.pi*df['R']) # V/m
df['E_phi'] = (df['U_loop'] - df['L_p']*df['dIp_dt']) / (2*np.pi*df['R'])
df[['E_phi_naive', 'E_phi']].hvplot(ylabel='E_phi [V/m]', grid=True)
In the beginning of the discharge the creationg of the poloidal magnetic field by the plasma current diminishes $E_\phi$, and at the end the plasma current and its field dissipates, enhancing $E_\phi$. With the estimated $E_\phi$, one can obtain an average temperature estimate with ${\langle j \rangle_a}$ and a (higher) core plasma temperature estimate with $j_0$, respectively.
for s in ('0', 'avg_a'):
for k in ('', '_naive'):
df[f'eta_{s}'+k] = df['E_phi'+k] / df[f'j_{s}']
df['eps'] = df['a'] / df['R']
for s in ('0', 'avg_a'):
for k in ('', '_naive'):
df[f'Te_{s}'+k] = electron_temperature_Spitzer_eV(df[f'eta_{s}'+k], eps=df['eps'])
df[['Te_0', 'Te_avg_a', 'Te_0_naive']].hvplot(ylabel='Te [eV]', grid=True)
plt.figure(figsize=(3, 2))
ax = df['Te_0'].plot.line()
ax.set(xlabel='time [ms]', ylabel='Te(r=0) [eV]')
plt.margins(0)
plt.tight_layout(pad=0.1)
plt.savefig('icon-fig.png')
A good estimate of the (line-averaged) electron density (concentration) is typically obtained from the microwave interferoemter. In the absence of this diagnostic an order-of-magntude estimate can be obtained using the ideal gas law applied to the initial inert state of the working gas. Since the whole chamber has a volume of $V_0\approx 60\,\mathrm{l}$, the working gas with the pre-discharge stationary equilibrium pressure $p_0$ at the room temperature $T_0\approx 300 \, \mathrm{K}$ will is expected to be composed of $N$ molecules according to the relation $$p_0 V_0 = N k_B T_0$$. One can assume that for a gven working gas the molecule dissasociates into $k_a$ atoms which can the fully ionaize giving $k_e$ electrons. Therefore, one can estimate the order-of-magnitude number of electrons (an upper estimate due to only partial ionaization of the working gas) as $$N_e\approx k_a k_e \frac{p_0 V_0}{k_B T_0}$$
def chamber_parameter(name):
r = requests.get(f'http://golem.fjfi.cvut.cz/shots/{shot_no}/Operation/Discharge/{name}')
v = r.content
try:
return float(v)
except ValueError:
return v.strip().decode()
p_0 = chamber_parameter('p_chamber_pressure_predischarge') *1e-3 # from mPa to Pa
working_gas = chamber_parameter('X_working_gas_discharge_request')
working_gas, p_0
('H', 0.00692)
if working_gas == 'H':
k_a = 2 # binary molecule
k_e = 1
elif working_gas == 'He':
k_a = 2
k_e =2
else:
raise RuntimeError(f'Unknown working gas {working_gas}')
V_0 = 60e-3 # m^3
T_0 = 300
N_e = k_a*k_e* (p_0 * V_0) / (T_0 * constants.k)
N_e
2.0048542388398496e+17
To estimate the actual electron density $n_e$ , i.e. number of electrons in $\mathrm{m}^{-3}$ one must estimate also the plasma volume $V_p$. Assuming a perfect plasma torus, its volume is tha cartesian product of its poloidal cross section (circular - $\pi a^2$) along the toroidal axis of the torus (length $2\pi R$), together $V_p=2\pi^2 R a^2$. The plasma density is then $n_e\approx N_e/V_p$.
df['V_p'] = 2*np.pi**2*df['R']*df['a']**2
df['n_e'] = N_e / df['V_p'] # in m^-3
df['n_e'].mean()
3.5144326039719875e+18
The thermal energy of electrons in the plasma $W_{th,e}$ evolves according to the applied heating power $P_H$ and the (turbulent and radiative) losses summarized by the loss power $P_L$ as $$\frac{d W_{th,e}}{dt}=P_H - P_L$$ The electron thermal energy can be approximated suing the plasma electron pressure $p_e=n_e k_B T_e$ as $ W_{th,e}\approx T_e k_B n_e V_p$.
df['p_e'] = df['n_e'] * df['Te_avg_a'] * constants.elementary_charge # Te is in eV, p_e will be in Pa
df['W_th_e'] = df['p_e'] * df['V_p'] # in Jouls
df[['p_e', 'W_th_e']].mean()
p_e 14.253594 W_th_e 0.813115 dtype: float64
In the absence of auxiliary heating systems such as NBI an ECRH, the only component of the heating power is the resistive (ohmic) heating power density due to the toroidal electric field and current $E_\phi j_\phi$ . Assuming a uniform distribution of this heating density, the total ohmic heating power can be estimated as $P_H=P_\Omega = E_\phi \langle j_\phi\rangle_a V_p$. Due to the geometric assumptions used above, this is equivalent to the total induced power with the change of the poloidal magnetic energy subtracted $$P_H = U_{loop} I_p - \frac{d}{dt}\left(\frac{1}{2} (L_e+L_i) I_p^2\right)$$
df['P_mag'] = df['L_p'] * df['Ip'] * df['dIp_dt'] # [kW] equivalent after chain rule
df['P_H'] = df['U_loop'] * df['Ip'] - df['P_mag'] # [kW]
A figure of merit critical for thermonuclear fusion is the characteristic time scale at which the thermal energy would be exponentially depleted under the assumption that the loss power is proportional to the stored thermal energy $P_L \propto W_{th}$. This time scale is called the energy confinement time $\tau_E$ and for the electron energy it can be estimated from the modified electron thermal energy balance with $P_L\approx W_{th,e}/\tau_{E,e}$ $$\frac{d W_{th,e}}{dt}= P_H - \frac{ W_{th,e}}{\tau_{E,e}}$$
df['dW_th_e_dt'] = signal.savgol_filter(df['W_th_e'].fillna(0), n_win, 3, 1, delta=dt) # [kW] 1. derivative of an order 3 polynomial lsq SG-filter
df['tau_E_e'] = df['W_th_e'] / (df['P_H'] - df['dW_th_e_dt']) # [ms] -< J/kW
df[['P_H', 'P_mag', 'dW_th_e_dt']].hvplot(grid=True, ylim=(-3, None), ylabel='Power [kW]')
kwd = dict(grid=True, title='', height=250, width=600)
kw = dict(xlabel='', ylim=(0, None), **kwd)
l = df['U_loop'].hvplot(ylabel='loop voltage [V]', **kw) +\
df['Ip'].hvplot(ylabel='plasma current [kA]', **kw) +\
df['a'].hvplot(ylabel='minor radius [m]', **kw) +\
df['q_a'].hvplot(ylabel='edge safety factor [1]', **kw) +\
df['Te_avg_a'].hvplot(ylabel='average elecron temperature [eV]', **kw) +\
df['tau_E_e'].hvplot(ylabel='el. energy confinement time [ms]', xlabel='time [ms]', ylim=(0, 0.5), **kwd)
l.cols(2)
df_overview=df[['q_a', 'E_phi', 'eps', 'V_p', 'Te_0', 'Te_avg_a', 'n_e', 'p_e', 'W_th_e', 'P_H', 'P_mag', 'tau_E_e']].describe().iloc[1:] # skip count
df_overview
q_a | E_phi | eps | V_p | Te_0 | Te_avg_a | n_e | p_e | W_th_e | P_H | P_mag | tau_E_e | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
mean | 20.133456 | 4.276317 | 2.125000e-01 | 5.704631e-02 | 52.654998 | 25.313883 | 3.514433e+18 | 14.253594 | 0.813115 | 16.840920 | -0.000554 | 0.060887 |
std | 1463.582566 | 1.140923 | 4.166311e-14 | 4.184353e-15 | 20.381528 | 9.798417 | 5.330175e+05 | 5.517235 | 0.314738 | 8.589505 | 0.858009 | 0.348729 |
min | -125901.486503 | 1.955366 | 2.125000e-01 | 5.704631e-02 | 0.237362 | 0.114112 | 3.514433e+18 | 0.064253 | 0.003665 | -0.272383 | -1.895565 | -14.558306 |
25% | 9.174539 | 3.135390 | 2.125000e-01 | 5.704631e-02 | 36.573287 | 17.582603 | 3.514433e+18 | 9.900310 | 0.564776 | 9.318195 | -0.662589 | 0.032168 |
50% | 12.587414 | 4.643121 | 2.125000e-01 | 5.704631e-02 | 51.057568 | 24.545918 | 3.514433e+18 | 13.821173 | 0.788447 | 16.862463 | -0.244776 | 0.046285 |
75% | 22.892807 | 5.363530 | 2.125000e-01 | 5.704631e-02 | 73.165060 | 35.174092 | 3.514433e+18 | 19.805623 | 1.129838 | 24.329066 | 0.832260 | 0.074633 |
max | 58027.842398 | 5.770294 | 2.125000e-01 | 5.704631e-02 | 82.496494 | 39.660177 | 3.514433e+18 | 22.331622 | 1.273937 | 32.512971 | 1.938918 | 29.535108 |
for agg in ('mean', 'std','min', 'max'):
for quantity, value in df_overview.loc[agg].iteritems():
print_and_save(quantity+'_'+agg, value)
q_a_mean = 20.13346 E_phi_mean = 4.27632 eps_mean = 0.21250 V_p_mean = 0.05705 Te_0_mean = 52.65500 Te_avg_a_mean = 25.31388 n_e_mean = 3514432603971987456.00000 p_e_mean = 14.25359 W_th_e_mean = 0.81311 P_H_mean = 16.84092 P_mag_mean = -0.00055 tau_E_e_mean = 0.06089 q_a_std = 1463.58257 E_phi_std = 1.14092 eps_std = 0.00000 V_p_std = 0.00000 Te_0_std = 20.38153 Te_avg_a_std = 9.79842 n_e_std = 533017.47458 p_e_std = 5.51724 W_th_e_std = 0.31474 P_H_std = 8.58951 P_mag_std = 0.85801 tau_E_e_std = 0.34873 q_a_min = -125901.48650 E_phi_min = 1.95537 eps_min = 0.21250 V_p_min = 0.05705 Te_0_min = 0.23736 Te_avg_a_min = 0.11411 n_e_min = 3514432603972520448.00000 p_e_min = 0.06425 W_th_e_min = 0.00367 P_H_min = -0.27238 P_mag_min = -1.89556 tau_E_e_min = -14.55831 q_a_max = 58027.84240 E_phi_max = 5.77029 eps_max = 0.21250 V_p_max = 0.05705 Te_0_max = 82.49649 Te_avg_a_max = 39.66018 n_e_max = 3514432603972520448.00000 p_e_max = 22.33162 W_th_e_max = 1.27394 P_H_max = 32.51297 P_mag_max = 1.93892 tau_E_e_max = 29.53511