The session survey for the 24-06-24

(psql command: SELECT shot_no,"X_discharge_command" FROM operation.discharges WHERE session_id LIKE "45402 %" ORDER BY shot_no ASC LIMIT 200)

Mission="Minimum Operation"

Staff="Dirigent"

#45402 (24-06-24 14:03:41)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=21" --comment "Standard discharge"


#45403 (24-06-24 14:08:44)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=20" --comment "Standard discharge"


#45404 (24-06-24 14:11:03)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=80" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=19" --comment "Standard discharge"


#45405 (24-06-24 14:15:07)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=80" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=19" --comment "Standard discharge"


#45406 (24-06-24 14:18:56)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=90,U_accel=70" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=19" --comment "Standard discharge"


#45407 (24-06-24 14:23:21)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=80,U_accel=60" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=19" --comment "Standard discharge"


#45408 (24-06-24 14:26:14)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=70,U_accel=50" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=19" --comment "Standard discharge"