Golem shot: 4544

2011-02-17 - 182709

Basic parameters:
  • Chamber pressure pchamber : 2.86->19.66 mPa (request: 20 mPa)
  • Chamber temperature: 0 grad C
  • CBt capacitors (23 mF) charged to: 500 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 975 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.34 over 6.07 to 15.41 [ms]
  • Mean toroidal magnetic field Bt: 0.123 T
  • Mean plasma current: 0.9 kA
  • Mean Uloop: 8.3 V
  • Break down voltage: 10.5 V
  • Plasma total charge: 5.3 C
  • Ohmic heating power: 7.5 kW
  • Q edge: 12.3
  • Central electron temperature: 20.4 eV

MirnovCoils

Diagnostics configuration

Thanks to the specific help and