Golem shot: 4546

2011-02-17 - 203248

Basic parameters:
  • Chamber pressure pchamber : 1.81->24.94 mPa (request: 20 mPa)
  • Chamber temperature: 0 grad C
  • CBt capacitors (# $TororoidalMagneticFieldCapacitorValue=23 mF) charged to: 500 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 8520 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.68 over 5.77 to 15.45 [ms]
  • Mean toroidal magnetic field Bt: 0.123 T
  • Mean plasma current: 0.9 kA
  • Mean Uloop: 8.0 V
  • Break down voltage: 11.2 V
  • Plasma total charge: 5.4 C
  • Ohmic heating power: 7.2 kW
  • Q edge: 12.3
  • Central electron temperature: 20.9 eV

Diagnostics: (configuration)

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and