Golem shot: 4568

2011-02-18 - 104906

Basic parameters:
  • Chamber pressure pchamber : 1.80->21.23 mPa (request: 20 mPa)
  • Chamber temperature: 0 grad C
  • CBt capacitors (23 mF) charged to: 1200 V
  • CBD capacitors (3.6 mF) charged to: 150 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 11797 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 6.51 over 8.79 to 15.3 [ms]
  • Mean toroidal magnetic field Bt: 0.248 T
  • Mean plasma current: 2.0 kA
  • Mean Uloop: 11.1 V
  • Break down voltage: 13.3 V
  • Plasma total charge: 17.6 C
  • Ohmic heating power: 22.2 kW
  • Q edge: 11.2
  • Central electron temperature: 28.6 eV

Diagnostics: (configuration)

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and