Golem shot: 4571

2011-02-18 - 110031

Basic parameters:
  • Chamber pressure pchamber : 1.86->20.74 mPa (request: 20 mPa)
  • Chamber temperature: 0 grad C
  • CBt capacitors (23 mF) charged to: 1200 V
  • CBD capacitors (3.6 mF) charged to: 150 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 50 V, triggered 5,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 12483 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 6.5 over 8.22 to 14.72 [ms]
  • Mean toroidal magnetic field Bt: 0.252 T
  • Mean plasma current: 2.0 kA
  • Mean Uloop: 10.9 V
  • Break down voltage: 13.2 V
  • Plasma total charge: 16.6 C
  • Ohmic heating power: 21.8 kW
  • Q edge: 11.4
  • Central electron temperature: 29.0 eV

Diagnostics: (configuration)

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and