The mission survey for the Experiments/PlasmaRegimes/0624Optimization

(psql command: SELECT shot_no,"X_discharge_command" FROM operation.discharges WHERE session_setup_name LIKE "0624Optimization %" ORDER BY shot_no ASC LIMIT 200)

Mission="Full steam"

Staff="Stepan, Lukas, Marek, Petr & Dirigent"

#45223 (24-06-13 10:27:22)     ./Dirigent.sh --discharge --operation.discharge "style='sujb'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=21" --comment "Discharge dlouhodobe stability"
























#45224 (24-06-13 10:51:19)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,U_cd=450,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=22.0" --comment "NI read test 1"
























#45225 (24-06-13 11:00:46)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,U_cd=450,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=22.0" --comment "NI read test 2"
























#45226 (24-06-13 11:06:52)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,U_cd=500,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=21.0" --comment "NI read test 3"
























#45227 (24-06-13 11:13:20)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,U_cd=500,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=20.9" --comment "NI read test 4"
























#45228 (24-06-14 12:33:11)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=21" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "Standard discharge"
























#45229 (24-06-14 12:39:59)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=21" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "Standard discharge"
























#45230 (24-06-14 13:19:09)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=550,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=4.9,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "RE Hunting Initial Test Discharge"
























#45231 (24-06-14 13:23:10)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=550,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=10,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "RE Hunting Initial Test Discharge p=10"
























#45232 (24-06-14 13:27:08)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=550,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=10,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "RE Hunting Initial Test Discharge p=10"
























#45233 (24-06-14 13:37:37)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=700,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=10,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "RE Hunting CD700V,5Pa"
























#45234 (24-06-14 13:41:12)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=700,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=5,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "RE Hunting CD700V,5Pa Repeat"
























#45235 (24-06-14 13:45:50)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=700,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=10,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT RE Hunting CD700V,10Pa"
























#45236 (24-06-14 13:51:39)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=650,t_Bt=0,U_cd=450,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=20,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT RE Hunting Bt650,CD450,20Pa"
























#45237 (24-06-14 13:56:21)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=650,t_Bt=0,U_cd=450,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=25,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT RE Hunting Bt650,CD450,25Pa"
























#45238 (24-06-14 13:59:55)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=450,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=20,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT RE Hunting Bt1150,CD450,20Pa"
























#45239 (24-06-14 14:04:01)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=450,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=25,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT RE Hunting Bt1150,CD450,25Pa"
























#45240 (24-06-14 14:10:40)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=550,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=5,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt1150,CD550,5Pa"
























#45241 (24-06-14 14:28:49)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=550,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=10,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt1150,CD550,10Pa"
























#45242 (24-06-14 14:34:18)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=700,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=5,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt1150,CD700,5Pa"
























#45243 (24-06-14 14:38:38)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=700,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=10,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt1150,CD700,10Pa"
























#45244 (24-06-14 14:44:18)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=650,t_Bt=0,U_cd=450,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=20,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt650,CD450,20Pa"
























#45245 (24-06-14 14:47:56)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=650,t_Bt=0,U_cd=450,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=25,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt650,CD450,25Pa"
























#45246 (24-06-14 14:51:43)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=450,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=20,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt650,CD450,20Pa"
























#45247 (24-06-14 14:55:27)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=450,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=25,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt1150,CD450,25Pa"
























#45248 (24-06-14 14:59:25)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=550,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=5,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt1150,CD550,5Pa"
























#45249 (24-06-14 15:03:56)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=550,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=10,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt1150,CD550,10Pa"
























#45250 (24-06-14 15:07:52)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=700,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=5,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt1150,CD700,5Pa"
























#45251 (24-06-14 15:11:54)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=700,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=10,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt1150,CD700,10Pa"
























#45252 (24-06-14 15:16:20)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=700,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=10,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt650,CD450,20Pa"
























#45253 (24-06-14 15:20:24)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=650,t_Bt=0,U_cd=450,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=25,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt650,CD450,25Pa"
























#45254 (24-06-14 15:25:23)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=450,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=20,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt650,CD450,20Pa"
























#45255 (24-06-14 15:29:12)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=450,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=25,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt1150,CD450,25Pa"
























#45256 (24-06-14 15:36:52)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=650,t_Bt=0,U_cd=450,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=20,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt650,CD450,20Pa"
























#45257 (24-06-14 15:40:42)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=550,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=5,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt1150,CD550,5Pa"
























#45258 (24-06-14 17:41:21)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=550,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=5,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt1150,CD550,5Pa"
























#45259 (24-06-14 17:44:41)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=550,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=10,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt1150,CD550,10Pa"
























#45260 (24-06-14 17:49:48)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=700,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=5,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt1150,CD700,5Pa"
























#45261 (24-06-14 17:55:14)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=700,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=10,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt1150,CD700,10Pa"
























#45262 (24-06-14 17:59:47)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=650,t_Bt=0,U_cd=450,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=20,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt650,CD450,20Pa"
























#45263 (24-06-14 18:03:11)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=650,t_Bt=0,U_cd=450,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=25,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt650,CD450,20Pa"
























#45264 (24-06-14 18:06:14)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=450,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=25,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt1150,CD450,25Pa"
























#45265 (24-06-14 18:20:18)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=450,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=20,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt650,CD450,20Pa"
























#45266 (24-06-14 18:23:40)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=550,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=5,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt1150,CD550,5Pa"
























#45267 (24-06-14 18:27:11)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=550,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=10,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt1150,CD550,10Pa"
























#45268 (24-06-14 18:30:47)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=700,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=5,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt1150,CD700,5Pa"
























#45269 (24-06-14 18:34:35)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=700,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=10,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt1150,CD700,10Pa"
























#45270 (24-06-14 18:38:02)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=650,t_Bt=0,U_cd=450,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=20,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt650,CD450,20Pa"
























#45271 (24-06-14 18:41:13)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=650,t_Bt=0,U_cd=450,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=25,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt650,CD450,25Pa"
























#45272 (24-06-14 18:44:21)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=450,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=20,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt650,CD450,20Pa"
























#45273 (24-06-14 18:47:45)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=450,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=25,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt1150,CD450,25Pa"
























#45274 (24-06-14 18:51:04)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=550,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=5,U_v=22.0" --infrastructure.positionstabilization "main_switch='off',radial_switch='off',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='off',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt1150,CD550,5Pa no stab"
























#45275 (24-06-14 18:54:03)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=700,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=5,U_v=22.0" --infrastructure.positionstabilization "main_switch='off',radial_switch='off',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='off',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt1150,CD700,5Pa no stab"
























#45276 (24-06-14 18:57:23)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=550,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=10,U_v=22.0" --infrastructure.positionstabilization "main_switch='off',radial_switch='off',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='off',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt1150,CD550,10Pa no stab"
























#45277 (24-06-14 19:00:46)     ./Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=450,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=20,U_v=22.0" --infrastructure.positionstabilization "main_switch='off',radial_switch='off',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='off',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "MarekT Bt650,CD450,20Pa no stab"
























#45358 (24-06-20 11:35:06)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=21" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "Standard discharge"
























#45359 (24-06-20 13:19:36)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,U_cd=500,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=21.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "test discharge"
























#45360 (24-06-20 13:23:14)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,U_cd=500,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=21.1" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "test discharge, repeat"
























#45361 (24-06-20 13:26:47)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,U_cd=500,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=21.1" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "test discharge, repeat 2"
























#45362 (24-06-20 14:11:15)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,U_cd=500,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=21.1" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "test discharge, after lunch"
























#45363 (24-06-20 14:19:48)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=550,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=5,U_v=21.1" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --diagnostics.doublerakeprobe "r_first_tip=100,X_mod='111111111111',I_SilverBox=0" --diagnostics.scintillationprobes "U_NIM_A1=600,U_NIM_A2=600,U_NIM_A3=600,U_NIM_A4=600" --diagnostics.langballpenprobe "r_lp_tip=90,S_mode_lp='float',R_lp_div_osc='10e3',R_lp_div_nosc='1e6',U_lp=-1,R_lp_isat='-1',R_bpp_div_osc='10e3',R_bpp_div_nosc='1e6'" --diagnostics.limitermirnovcoils "vacuum_shot='-1'" --diagnostics.stripdetector "acq_time=200,acq_delay=200,acq_mode='0'" --comment "repeating RE discharge 45240"
























#45364 (24-06-20 14:51:14)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=550,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=5,U_v=21.1" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --diagnostics.doublerakeprobe "r_first_tip=100,X_mod='111111111111',I_SilverBox=0" --diagnostics.scintillationprobes "U_NIM_A1=600,U_NIM_A2=600,U_NIM_A3=600,U_NIM_A4=600" --diagnostics.langballpenprobe "r_lp_tip=95,S_mode_lp='float',R_lp_div_osc='10e3',R_lp_div_nosc='1e6',U_lp=-1,R_lp_isat='-1',R_bpp_div_osc='10e3',R_bpp_div_nosc='1e6'" --diagnostics.limitermirnovcoils "vacuum_shot='-1'" --diagnostics.stripdetector "acq_time=200,acq_delay=200,acq_mode='0'" --comment "repeating RE discharge 45240, run 2"
























#45365 (24-06-20 15:18:41)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=550,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=10,U_v=21.1" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --diagnostics.doublerakeprobe "r_first_tip=100,X_mod='111111111111',I_SilverBox=0" --diagnostics.scintillationprobes "U_NIM_A1=600,U_NIM_A2=600,U_NIM_A3=600,U_NIM_A4=600" --diagnostics.langballpenprobe "r_lp_tip=100,S_mode_lp='float',R_lp_div_osc='10e3',R_lp_div_nosc='1e6',U_lp=-1,R_lp_isat='-1',R_bpp_div_osc='10e3',R_bpp_div_nosc='1e6'" --diagnostics.limitermirnovcoils "vacuum_shot='-1'" --diagnostics.stripdetector "acq_time=200,acq_delay=200,acq_mode='0'" --comment "repeating RE discharge 45240, run 3"
























#45366 (24-06-20 15:31:36)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=550,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=10,U_v=22.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --diagnostics.doublerakeprobe "r_first_tip=100,X_mod='111111111111',I_SilverBox=0" --diagnostics.scintillationprobes "U_NIM_A1=600,U_NIM_A2=600,U_NIM_A3=600,U_NIM_A4=600" --diagnostics.langballpenprobe "r_lp_tip=90,S_mode_lp='float',R_lp_div_osc='10e3',R_lp_div_nosc='1e6',U_lp=-1,R_lp_isat='-1',R_bpp_div_osc='10e3',R_bpp_div_nosc='1e6'" --diagnostics.limitermirnovcoils "vacuum_shot='-1'" --diagnostics.stripdetector "acq_time=200,acq_delay=200,acq_mode='0'" --comment "repeating 45267"
























#45367 (24-06-20 15:43:23)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=21" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "Standard discharge"
























#45368 (24-06-20 15:58:00)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=750,t_Bt=0,U_cd=500,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=70" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=21,U_v=22.0" --infrastructure.positionstabilization "main_switch='off',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "DT MP01"
























#45369 (24-06-20 16:01:13)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=750,t_Bt=0,U_cd=500,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=70" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=21,U_v=22.0" --infrastructure.positionstabilization "main_switch='off',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "DT MP01"
























#45370 (24-06-20 16:07:01)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=850,t_Bt=0,U_cd=500,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=70" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=21,U_v=22.0" --infrastructure.positionstabilization "main_switch='off',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "DT MP02"
























#45371 (24-06-20 16:10:22)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=950,t_Bt=0,U_cd=500,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=70" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=21,U_v=22.0" --infrastructure.positionstabilization "main_switch='off',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "DT MP03"
























#45372 (24-06-20 16:13:43)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1050,t_Bt=0,U_cd=500,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=70" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=21,U_v=22.0" --infrastructure.positionstabilization "main_switch='off',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "DT MP04"
























#45373 (24-06-20 16:17:39)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=500,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=70" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=21,U_v=22.0" --infrastructure.positionstabilization "main_switch='off',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "DT MP05"
























#45374 (24-06-20 16:27:27)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=500,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=70" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=21,U_v=22.0" --infrastructure.positionstabilization "main_switch='off',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "DT MP05"
























#45375 (24-06-20 16:32:28)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=750,t_Bt=0,U_cd=650,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=70" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=21,U_v=22.0" --infrastructure.positionstabilization "main_switch='off',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "DT MP06"
























#45376 (24-06-20 16:38:00)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=850,t_Bt=0,U_cd=650,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=70" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=21,U_v=22.0" --infrastructure.positionstabilization "main_switch='off',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "DT MP07"
























#45377 (24-06-20 16:41:59)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=950,t_Bt=0,U_cd=650,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=70" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=21,U_v=22.0" --infrastructure.positionstabilization "main_switch='off',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "DT MP08"
























#45378 (24-06-20 16:50:05)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1050,t_Bt=0,U_cd=650,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=70" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=21,U_v=22.0" --infrastructure.positionstabilization "main_switch='off',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "DT MP09"
























#45379 (24-06-20 16:54:52)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1050,t_Bt=0,U_cd=650,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=70" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=21,U_v=19.3" --infrastructure.positionstabilization "main_switch='off',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "DT MP09"
























#45380 (24-06-20 16:58:34)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=650,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=70" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=21,U_v=19.5" --infrastructure.positionstabilization "main_switch='off',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "DT MP10"
























#45381 (24-06-20 17:17:49)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=700,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=5,U_v=19.3" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "RE tuning 45268"
























#45382 (24-06-20 18:12:56)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=700,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=5,U_v=19.3" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "RE tuning 45268; after GD"
























#45383 (24-06-20 18:19:27)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=700,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=5,U_v=13.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "RE tuning 45268; after GD"
























#45384 (24-06-20 18:26:09)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=550,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=5,U_v=13.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "RE tuning CD550; after GD"
























#45385 (24-06-20 18:37:04)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=450,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=20,U_v=17" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,-5;7000,-10;11000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "RE tuning after GD"
























#45386 (24-06-20 18:47:39)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=550,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=15" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;7000,-5;10000,-11;14000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "RE tuning shifted stab"
























#45387 (24-06-20 19:02:54)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=550,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=15" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;7000,-5;10000,-11;14000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;4000,-5;8000,-10;11000,-20;30000,0'" --comment "RE tuning shifted stab repeat after quick GD"
























#45388 (24-06-21 10:32:08)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=21" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "Standard discharge"
























#45389 (24-06-21 10:42:29)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=400,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=25,U_v=20.6" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-5;13000,-10;17000,-14;20000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;10000,-5;13000,-10;17000,-14;20000,-20;30000,0'" --comment "RE hunting"
























#45390 (24-06-21 11:13:20)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1100,t_Bt=0,U_cd=400,t_cd=0,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=25,U_v=20.6" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-5;13000,-10;17000,-14;20000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;10000,-5;13000,-10;17000,-14;20000,-20;30000,0'" --comment "RE hunting 2"
























#45391 (24-06-21 11:20:59)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=400,t_cd=5000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=25,U_v=20.6" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-5;13000,-10;17000,-14;20000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;10000,-5;13000,-10;17000,-14;20000,-20;30000,0'" --comment "RE hunting 3"
























#45392 (24-06-21 11:28:36)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=900,t_Bt=0,U_cd=400,t_cd=0,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=25,U_v=20.7" --infrastructure.positionstabilization "main_switch='off',radial_switch='on',radial_waveform='1000,0;10000,-5;13000,-10;17000,-14;20000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;10000,-5;13000,-10;17000,-14;20000,-20;30000,0'" --comment "RE hunting 4"
























#45393 (24-06-21 11:51:55)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=700,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=5,U_v=16.5" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-5;13000,-10;17000,-14;20000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;10000,-5;13000,-10;17000,-14;20000,-20;30000,0'" --comment "repeating 45383"
























#45394 (24-06-21 12:07:31)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=700,t_cd=2000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='p_pid',S_gas='H',p_H=5,U_v=16.5" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;11000,-5;14000,-10;18000,-14;21000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-5;14000,-10;18000,-14;21000,-20;30000,0'" --comment "repeating 45383"
























#45395 (24-06-21 12:16:31)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=700,t_cd=10000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=5,U_v=16.5" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;20000,-5;23000,-10;27000,-14;30000,-20;40000,0',vertical_switch='on',vertical_waveform='1000,0;20000,-5;23000,-10;27000,-14;31000,-20;40000,0'" --comment "45394 with 10ms delay"
























#45396 (24-06-21 12:22:21)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=550,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=5,U_v=13.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;11000,-5;14000,-10;18000,-14;21000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-5;14000,-10;18000,-14;21000,-20;30000,0'" --comment "repeating 45384"
























#45397 (24-06-21 12:37:26)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=550,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=5,U_v=13.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;11000,-5;14000,-10;18000,-14;21000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-5;14000,-10;18000,-14;21000,-20;30000,0'" --comment "repeating 45384,after gd"
























#45398 (24-06-21 12:46:14)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1150,t_Bt=0,U_cd=550,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=13.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;11000,-5;14000,-10;18000,-14;21000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-5;14000,-10;18000,-14;21000,-20;30000,0'" --comment "repeating 45384,after gd"
























#45409 (24-06-24 15:09:29)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=500,t_cd=0,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.3" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;2000,-20;13000,-20;20000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-20;13000,-20;20000,-20;30000,0'" --comment "RE hunting shot1"
























#45410 (24-06-24 15:15:09)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=500,t_cd=0,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.3" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;2000,-20;5000,-20;20000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;5000,-20;13000,-20;20000,-20;30000,0'" --comment "RE hunting shot1"
























#45411 (24-06-24 15:19:31)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=500,t_cd=0,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.3" --infrastructure.positionstabilization "main_switch='off',radial_switch='off',radial_waveform='1000,0;2000,-20;5000,-20;20000,-20;30000,0',vertical_switch='off',vertical_waveform='1000,0;5000,-20;13000,-20;20000,-20;30000,0'" --comment "RE hunting shot1"
























#45412 (24-06-24 15:25:39)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=500,t_cd=0,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.1" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;7000,-20;20000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;7000,-20;13000,-20;20000,-20;30000,0'" --comment "RE hunting shot1"
























#45413 (24-06-25 13:21:00)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=21" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "Standard discharge"
























#45414 (24-06-25 13:25:27)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=20" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=80" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "Standard discharge"
























#45415 (24-06-25 13:31:41)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,O_Bt='CW',U_cd=450,t_cd=0,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=19.1" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=80" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;8000,-20;20000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-10;20000,-10;30000,0'" --comment "long disch shot1"
























#45416 (24-06-25 13:51:48)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,O_Bt='CW',U_cd=450,t_cd=0,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=19.2" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=80" --infrastructure.positionstabilization "main_switch='off',radial_switch='off',radial_waveform='1000,0;8000,-20;20000,-20;30000,0',vertical_switch='off',vertical_waveform='1000,0;11000,-10;20000,-10;30000,0'" --comment "long disch shot1"
























#45417 (24-06-25 13:55:44)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,O_Bt='CW',U_cd=400,t_cd=0,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=19.2" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=80" --infrastructure.positionstabilization "main_switch='off',radial_switch='off',radial_waveform='1000,0;8000,-20;20000,-20;30000,0',vertical_switch='off',vertical_waveform='1000,0;11000,-10;20000,-10;30000,0'" --comment "long disch shot3"
























#45418 (24-06-25 14:01:07)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,O_Bt='CW',U_cd=350,t_cd=0,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=19.2" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=80" --infrastructure.positionstabilization "main_switch='off',radial_switch='off',radial_waveform='1000,0;8000,-20;20000,-20;30000,0',vertical_switch='off',vertical_waveform='1000,0;11000,-10;20000,-10;30000,0'" --comment "long disch shot4"
























#45419 (24-06-25 14:04:56)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,O_Bt='CW',U_cd=300,t_cd=0,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=19.2" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=80" --infrastructure.positionstabilization "main_switch='off',radial_switch='off',radial_waveform='1000,0;8000,-20;20000,-20;30000,0',vertical_switch='off',vertical_waveform='1000,0;11000,-10;20000,-10;30000,0'" --comment "long disch shot5"
























#45420 (24-06-25 14:09:50)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,O_Bt='CW',U_cd=300,t_cd=3000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=19.2" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=80" --infrastructure.positionstabilization "main_switch='off',radial_switch='off',radial_waveform='1000,0;8000,-20;20000,-20;30000,0',vertical_switch='off',vertical_waveform='1000,0;11000,-10;20000,-10;30000,0'" --comment "long disch shot6"
























#45421 (24-06-25 14:16:16)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,O_Bt='CW',U_cd=600,t_cd=15000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=19.2" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=80" --infrastructure.positionstabilization "main_switch='off',radial_switch='off',radial_waveform='1000,0;8000,-20;20000,-20;30000,0',vertical_switch='off',vertical_waveform='1000,0;11000,-10;20000,-10;30000,0'" --comment "long disch shot7"
























#45422 (24-06-25 14:19:35)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=1000,t_Bt=0,O_Bt='CW',U_cd=700,t_cd=15000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=19.2" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=80" --infrastructure.positionstabilization "main_switch='off',radial_switch='off',radial_waveform='1000,0;8000,-20;20000,-20;30000,0',vertical_switch='off',vertical_waveform='1000,0;11000,-10;20000,-10;30000,0'" --comment "long disch shot7"
























#45423 (24-06-25 15:57:15)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,O_Bt='CW',U_cd=300,t_cd=0,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=19.2" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=80" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;6000,-20;20000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;6000,-20;20000,-20;30000,0'" --comment "300UCd add_stab"
























#45424 (24-06-25 16:03:54)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,O_Bt='CW',U_cd=300,t_cd=0,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=19.2" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=80" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;6000,-10;110000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;6000,-10;11000,-20;30000,0'" --comment "300UCd add_stab"
























#45425 (24-06-25 16:11:01)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,O_Bt='CW',U_cd=300,t_cd=0,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=19.2" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=80" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;6000,-5;110000,-10;15000,-15;30000,0',vertical_switch='on',vertical_waveform='1000,0;6000,-5;11000,-10;30000,0'" --comment "300UCd add_stab"
























#45426 (24-06-25 16:19:32)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,O_Bt='CW',U_cd=300,t_cd=0,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=19.4" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=80" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;5000,-5;80000,-10;15000,-15;30000,0',vertical_switch='on',vertical_waveform='1000,0;5000,-5;9000,-10;30000,0'" --comment "300UCd add_stab"
























#45427 (24-06-25 16:23:45)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=500,t_cd=0,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.1" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;7000,-20;20000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;7000,-20;13000,-20;20000,-20;30000,0'" --comment "RE hunting repeat"
























#45428 (24-06-25 16:40:04)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=0,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.1" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;7000,-15;20000,-15;30000,0',vertical_switch='on',vertical_waveform='1000,0;7000,-15;13000,-15;20000,-15;30000,0'" --comment "RE hunting repeat"
























#45429 (24-06-25 16:44:56)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=0,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.1" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;7000,-20;20000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;7000,-15;13000,-15;20000,-15;30000,0'" --comment "RE hunting repeat"
























#45430 (24-06-25 16:50:03)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=0,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.1" --infrastructure.positionstabilization "main_switch='off',radial_switch='off',radial_waveform='1000,0;7000,-20;20000,-20;30000,0',vertical_switch='off',vertical_waveform='1000,0;7000,-15;13000,-15;20000,-15;30000,0'" --comment "RE hunting repeat"
























#45431 (24-06-25 16:57:10)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=0,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.1" --infrastructure.positionstabilization "main_switch='off',radial_switch='off',radial_waveform='1000,0;11000,-20;20000,-20;30000,0',vertical_switch='off',vertical_waveform='1000,0;11000,-10;13000,-10;20000,-10;30000,0'" --comment "RE hunting repeat"
























#45432 (24-06-25 17:13:12)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=80" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.1" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;22000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;23000,-20;30000,0'" --comment "RE hunting repeat"
























#45489 (24-06-26 16:04:33)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=80,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.1" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "repeat 39125"
























#45490 (24-06-26 16:12:22)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "repeat 39125"
























#45491 (24-06-26 16:17:38)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "repeat 39125"
























#45492 (24-06-26 16:32:31)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=80,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "repeat 39125"
























#45493 (24-06-26 16:36:17)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "repeat 39125"
























#45494 (24-06-26 16:40:17)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.0" --infrastructure.positionstabilization "main_switch='off',radial_switch='off',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='off',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "repeat 39125"
























#45495 (24-06-26 16:47:06)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "repeat 39123"
























#45496 (24-06-26 16:51:50)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=21" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "Standard discharge"
























#45497 (24-06-26 16:56:11)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=21" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "Standard discharge"
























#45498 (24-06-26 17:00:57)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=21" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "Standard discharge"
























#45499 (24-06-26 17:04:56)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "repeat 39123"
























#45500 (24-06-26 17:11:04)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=80,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "repeat 39123"
























#45501 (24-06-26 17:25:16)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=80,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.4" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "repeat 39123"
























#45502 (24-06-26 17:35:18)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.4" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "higher U_heater"
























#45503 (24-06-26 17:40:45)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "higher U_heater"
























#45504 (24-06-26 17:56:35)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=425,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "higher U_heater"
























#45505 (24-06-26 18:01:54)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=475,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "higher U_heater"
























#45506 (24-07-01 12:07:34)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=21" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "Standard discharge"
























#45507 (24-07-01 12:19:48)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.7" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment " start - repeat 45502"
























#45508 (24-07-01 12:32:53)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.4" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment " repeat 45502"
























#45509 (24-07-01 12:45:59)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.3" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment " repeat 45502"
























#45510 (24-07-01 12:55:40)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=21" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "Standard discharge"
























#45511 (24-07-01 13:01:14)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=21" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "Standard discharge"
























#45512 (24-07-01 13:05:37)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=21" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "Standard discharge"
























#45513 (24-07-01 13:12:39)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=21" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "Standard discharge"
























#45514 (24-07-01 13:18:42)     ./Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=21" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --comment "Standard discharge"
























#45515 (24-07-01 13:33:56)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.3" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment " repeat 45502"
























#45516 (24-07-01 13:38:12)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.5" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment " repeat 45502"
























#45517 (24-07-01 15:47:16)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1300,t_Bt=0,U_cd=400,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.5" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "search RE regime"
























#45518 (24-07-01 15:53:51)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1300,t_Bt=0,U_cd=400,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=21.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "search RE regime"
























#45519 (24-07-01 15:59:08)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1300,t_Bt=0,U_cd=500,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.5" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "search RE regime"
























#45520 (24-07-01 16:07:01)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1300,t_Bt=0,U_cd=500,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.8" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "search RE regime"
























#45521 (24-07-01 16:15:27)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1300,t_Bt=0,U_cd=500,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.8" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;5000,-5;7000,-10;9000,-15;10000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;5000,-5;7000,-10;9000,-15;10000,-20;24000,-20;30000,0'" --comment "search RE regime, staged stab"
























#45522 (24-07-01 16:25:06)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1300,t_Bt=0,U_cd=500,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.9" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;6000,-5;8000,-12;10000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;5000,-5;7000,-10;9000,-15;10000,-20;24000,-20;30000,0'" --comment "search RE regime, staged stab, shift radial"
























#45523 (24-07-01 16:39:52)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1300,t_Bt=0,U_cd=500,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.9" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;6000,-5;8000,-12;10000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;5000,-5;7000,-10;9000,-15;10000,-20;24000,-20;30000,0'" --comment "search RE regime, repeat after GD"
























#45524 (24-07-01 16:43:52)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1300,t_Bt=0,U_cd=500,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.9" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;6000,5;8000,12;10000,20;24000,20;30000,0',vertical_switch='on',vertical_waveform='1000,0;5000,-5;7000,-10;9000,-15;10000,-20;24000,-20;30000,0'" --comment "search RE regime; radial stab inverted"
























#45525 (24-07-01 16:50:14)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1300,t_Bt=0,U_cd=500,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.0" --infrastructure.positionstabilization "main_switch='on',radial_switch='off',radial_waveform='1000,0;6000,5;8000,12;10000,20;24000,20;30000,0',vertical_switch='on',vertical_waveform='1000,0;5000,-5;7000,-10;9000,-15;10000,-20;24000,-20;30000,0'" --comment "search RE regime; no radial stab"
























#45526 (24-07-01 16:55:38)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1300,t_Bt=0,U_cd=500,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.9" --infrastructure.positionstabilization "main_switch='off',radial_switch='off',radial_waveform='1000,0;6000,5;8000,12;10000,20;24000,20;30000,0',vertical_switch='on',vertical_waveform='1000,0;5000,-5;7000,-10;9000,-15;10000,-20;24000,-20;30000,0'" --comment "search RE regime no stab"
























#45527 (24-07-01 17:03:31)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1300,t_Bt=0,U_cd=500,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.9" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;6000,-5;8000,-12;10000,-20;24000,-20;30000,0',vertical_switch='off',vertical_waveform='1000,0;5000,-5;7000,-10;9000,-15;10000,-20;24000,-20;30000,0'" --comment "search RE regime only radial stab (normal orientation)"
























#45528 (24-07-01 17:10:54)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1300,t_Bt=0,U_cd=500,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.9" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;6000,-5;8000,-12;10000,-20;24000,-20;30000,0',vertical_switch='off',vertical_waveform='1000,0;5000,-5;7000,-10;9000,-15;10000,-20;24000,-20;30000,0'" --comment "search RE repeating previous with fixed preion"
























#45529 (24-07-01 17:16:30)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=500,t_Bt=0,U_cd=500,t_cd=10000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.9" --infrastructure.positionstabilization "main_switch='off',radial_switch='off',radial_waveform='1000,0;6000,5;8000,12;10000,20;24000,20;30000,0',vertical_switch='off',vertical_waveform='1000,0;5000,-5;7000,-10;9000,-15;10000,-20;24000,-20;30000,0'" --comment "search RE regime test shifted BT"
























#45530 (24-07-01 17:19:32)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=300,t_Bt=0,U_cd=500,t_cd=10000,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.9" --infrastructure.positionstabilization "main_switch='off',radial_switch='off',radial_waveform='1000,0;6000,5;8000,12;10000,20;24000,20;30000,0',vertical_switch='off',vertical_waveform='1000,0;5000,-5;7000,-10;9000,-15;10000,-20;24000,-20;30000,0'" --comment "search RE regime test shifted BT"
























#45531 (24-07-01 17:37:26)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=80,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.4" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "attempt for 45501 longest discharge; agter GD"
























#45532 (24-07-01 17:41:44)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.4" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "repeating 45502"
























#45533 (24-07-01 17:46:54)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.4" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "repeating 45502; attept 2"
























#45534 (24-07-01 18:02:41)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.4" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "last one, Fluke outside"
























#45535 (24-07-01 18:06:44)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.4" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "Fluke outside 2"
























#45536 (24-07-01 18:11:10)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.4" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "Fluke outside 3"
























#45537 (24-07-01 18:16:30)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.4" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "Fluke outside 4"
























#45538 (24-07-01 18:37:07)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.4" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "Fluke outside 1, even further"
























#45539 (24-07-01 18:42:53)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "Fluke outside 2, even further"
























#45540 (24-07-01 18:47:04)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "Fluke outside 3, even further"
























#45541 (24-07-01 18:51:37)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "Fluke outside 4, even further"
























#45542 (24-07-01 18:57:55)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1200,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.2" --infrastructure.positionstabilization "main_switch='off',radial_switch='off',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='off',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "Fluke outside 4, even further; no stab"
























#45543 (24-07-01 19:05:45)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1100,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;12000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "searching good regime"
























#45544 (24-07-01 19:10:18)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1100,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "searching good regime"
























#45545 (24-07-01 19:25:04)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1100,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "searching good regime"
























#45546 (24-07-01 19:28:44)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1100,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "searching good regime"
























#45547 (24-07-01 19:32:50)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1100,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "searching good regime"
























#45548 (24-07-01 19:40:25)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1100,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "searching good regime"
























#45549 (24-07-01 19:45:34)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1100,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "searching good regime"
























#45550 (24-07-01 19:51:36)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1100,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "searching good regime"
























#45551 (24-07-01 19:55:23)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1100,t_Bt=0,U_cd=450,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "searching good regime"
























#45552 (24-07-01 20:00:37)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1100,t_Bt=0,U_cd=425,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "searching good regime"
























#45553 (24-07-01 20:05:35)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1050,t_Bt=0,U_cd=425,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "searching good regime"
























#45554 (24-07-01 20:11:23)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1050,t_Bt=0,U_cd=400,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "searching good regime"
























#45555 (24-07-01 20:16:07)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1000,t_Bt=0,U_cd=425,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=10.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "searching good regime"
























#45556 (24-07-01 20:24:20)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1000,t_Bt=0,U_cd=425,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=10.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;16000,-10;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "searching good regime"
























#45557 (24-07-01 20:30:12)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1000,t_Bt=0,U_cd=425,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=10.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;17000,-15;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "searching good regime"
























#45558 (24-07-01 20:34:31)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1000,t_Bt=0,U_cd=425,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=10.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "searching good regime"
























#45559 (24-07-01 20:40:46)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1000,t_Bt=0,U_cd=425,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=10.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "searching good regime"
























#45560 (24-07-01 20:44:44)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1000,t_Bt=0,U_cd=425,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=10.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "searching good regime"
























#45561 (24-07-01 20:48:39)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1000,t_Bt=0,U_cd=425,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=10.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "searching good regime"
























#45562 (24-07-01 20:53:35)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=950,t_Bt=0,U_cd=425,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=10.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "searching good regime"
























#45563 (24-07-01 20:58:09)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=950,t_Bt=0,U_cd=400,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=10.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "searching good regime"
























#45564 (24-07-01 21:02:39)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=950,t_Bt=0,U_cd=400,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=10.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "searching good regime"
























#45624 (24-07-04 10:58:43)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1050,t_Bt=0,U_cd=425,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "searching good regime"
























#45625 (24-07-04 11:08:08)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1050,t_Bt=0,U_cd=425,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=20.2" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "with CdTe det"
























#45626 (24-07-04 11:17:43)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1050,t_Bt=0,U_cd=425,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.5" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "repeat"
























#45627 (24-07-04 11:23:46)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1050,t_Bt=0,U_cd=425,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=19.5" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'" --comment "p 10"