Golem shot: 4609

2011-02-18 - 160220

Basic parameters:
  • Chamber pressure pchamber : 1.69->24.56 mPa (request: 20 mPa)
  • Chamber temperature: 0 grad C
  • CBt capacitors (23 mF) charged to: 500 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 30557 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.23 over 9.82 to 18.05 [ms]
  • Mean toroidal magnetic field Bt: 0.140 T
  • Mean plasma current: 2.2 kA
  • Mean Uloop: -0.1 V
  • Break down voltage: -0.2 V
  • Plasma total charge: 21.8 C
  • Ohmic heating power: 0.2 kW
  • Q edge: 5.7
  • Central electron temperature: 705.1 eV

Diagnostics: (configuration)

MirnovCoils_JK

FastCameraExilim

Analysis:

SafetyFactor_JK

Thanks to the specific help and