Golem shot: 4617

2011-02-18 - 164217

Basic parameters:
  • Chamber pressure pchamber : 1.68->39.08 mPa (request: 40 mPa)
  • Chamber temperature: 0 grad C
  • CBt capacitors (23 mF) charged to: 700 V
  • CBD capacitors (3.6 mF) charged to: 150 V, triggered 3,5 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 32960 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.21 over 9.55 to 17.76 [ms]
  • Mean toroidal magnetic field Bt: 0.194 T
  • Mean plasma current: 2.0 kA
  • Mean Uloop: -0.1 V
  • Break down voltage: -0.3 V
  • Plasma total charge: 18.7 C
  • Ohmic heating power: 0.2 kW
  • Q edge: 8.8
  • Central electron temperature: 661.7 eV

Diagnostics: (configuration)

MirnovCoils_JK

FastCameraExilim

Analysis:

SafetyFactor_JK

Thanks to the specific help and