The session survey for the 24-09-02

(psql command: SELECT shot_no,"X_discharge_command" FROM operation.discharges WHERE session_id LIKE "46203 %" ORDER BY shot_no ASC LIMIT 200)

Mission="Full steam"

Staff="Stepan, Lukas, Marek, Petr & Dirigent"

#46203 (24-09-02 10:26:40)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1100,t_Bt=0,U_cd=325,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;20000,-20;40000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;19000,-20;40000,0'" --infrastructure.currentstabilization "main_switch='off',waveform='1000,0;15000,-20;20000,20;30000,-20;40000,0'" --comment "test - standard good discharge"


























#46204 (24-09-02 10:30:56)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1100,t_Bt=0,U_cd=325,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;20000,-20;40000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;19000,-20;40000,0'" --infrastructure.currentstabilization "main_switch='off',waveform='1000,0;15000,-20;20000,20;30000,-20;40000,0'" --comment "test - standard good discharge"


























#46205 (24-09-02 10:35:59)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1100,t_Bt=0,U_cd=325,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;20000,-20;40000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;19000,-20;40000,0'" --infrastructure.currentstabilization "main_switch='off',waveform='1000,0;15000,-20;20000,20;30000,-20;40000,0'" --comment "test - standard good discharge"


























#46206 (24-09-02 10:41:46)     ./Dirigent.sh --discharge --operation.discharge "style='sujb'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=21" --comment "Discharge dlouhodobe stability"