16:48:55 #46278   PingAllDevices:	               
16:48:56 #46278   CheckAbilityToMakeDischarge:	Ping OK              
16:48:56 #46278   LogTheFunctionAction:	The Function PrepareEnvironment@SHM on stage ..          
16:48:57 #46278   PrepareDischargeEnv@SHM:	Copying Default infrastructure.preionization to /dev/shm/golem/ActualShot/Production/Parameters ..               
16:48:57 #46278   PrepareDischargeEnv@SHM:	Copying Default diagnostics.limitermirnovcoils to /dev/shm/golem/ActualShot/Production/Parameters ..               
16:48:57 #46278   PrepareDischargeEnv@SHM:	./Dirigent.sh \ \n--discharge --operation.discharge "style='standard',vacuum_shot='-1'" \\n--infrastructure.bt_ecd "U_Bt=0,t_Bt=0,O_Bt='CW',U_cd=0,t_cd=1000,O_cd='CW'"  \\n--infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100"  \\n--infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=15,U_v=0" \\n--infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;2000,-20;22000,0;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,0;22000,0;50000,0;55000,10'" 
16:48:57 #46279   PrepareDischargeEnv@SHM:	Command Line Request: Calibration of magnetic fields with 3D Hall probe               
16:48:58 #46279   Relay:	#1@Miscellaneous  (Engage12V_24V_intosystem@Miscellaneous) goes ON ..                
16:48:58 #46279   Relay:	#1@Miscellaneous  (Engage12V_24V_intosystem@Miscellaneous) goes ON ..                
16:48:58 #46279   Relay:	#1@Vacuum  (Majak@Vacuum) goes ON ..                
16:48:58 #46279   Relay:	#7@MiscII  (SignalTowerOrangeGreen@MiscII) goes ON ..                
16:48:58 #46279   GetReadyTheDischarge:	Going with gas type H               
16:48:58 #46279   Relay:	#12@PositionStabilization  (MainSwitch4PositionStabilization) goes ON ..                
16:48:58 #46279   Relay:	#12@Vacuum  (H2-pipe@Vacuum) goes ON ..                
16:48:58 #46279   GetReadyTheDischarge:	Going with gas pressure requested via U_v request               
16:48:58 #46279   VacuumLog:	p_ch=54700000.00/15 mPa,T_ch=29.9 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:48:58 #46279   GetReadyTheDischarge:	Diving into ..             
16:48:58 #46279   GetReadyTheDischarge:	Discharge with Bt CW request               
16:48:59 #46279   GetReadyTheDischarge:	Discharge with CD CW request               
16:49:01 #46279   Relay:	#2@Miscellaneous  (Preionization-Heater@Miscellaneous) goes ON ..                
16:49:02 #46279   GetReadyTheDischarge:	Bt capacitor charging not requested               
16:49:02 #46279   GetReadyTheDischarge:	Cd capacitor charging not requested               
16:49:02 #46279   GetReadyTheDischarge:	U_Bt: 0, Hrana: 98               
16:49:02 #46279   GetReadyTheDischarge:	U_Et: 0, Hrana: 98               
16:49:02 #46279   ChargingResistorsAllON:	Diving into ..             
16:49:02 #46279   GetReadyTheDischarge:	Ascending from ..             
#2@PowerSupplies  (PowerSupplyHVcontactor@PowerSupplies) goes OFF ..                
16:49:03 #46279   Relay:	#4@Miscellaneous  (Preionization-Engage@Miscellaneous) goes ON ..                
16:49:05 #46279   GetReadyTheDischarge:	We have got 0 V for -1 mPa request               
16:49:06 #46279   VacuumLog:	p_ch=54700000.00/15 mPa,T_ch=29.9 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:49:09 #46279   VacuumLog:	p_ch=54700000.00/15 mPa,T_ch=30.0 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:49:13 #46279   VacuumLog:	p_ch=54700000.00/15 mPa,T_ch=29.9 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:49:13 #46279   Relay:	#3@Miscellaneous  (Preionization-Shortcut@Miscellaneous) goes ON ..                
16:49:17 #46279   VacuumLog:	p_ch=54700000.00/15 mPa,T_ch=29.9 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:49:20 #46279   VacuumLog:	p_ch=54700000.00/15 mPa,T_ch=30.0 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:49:24 #46279   VacuumLog:	p_ch=54800000.00/15 mPa,T_ch=29.8 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:49:28 #46279   VacuumLog:	p_ch=54800000.00/15 mPa,T_ch=29.9 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:49:31 #46279   VacuumLog:	p_ch=54800000.00/15 mPa,T_ch=29.9 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:49:35 #46279   VacuumLog:	p_ch=54800000.00/15 mPa,T_ch=29.9 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:49:36 #46279   Relay:	#8@MiscII  (SignalTowerRed@MiscII) goes ON ..                
16:49:36 #46279   LogTheDeviceAction:	The TektrMSO56-a.sh action on stage with Arming         
16:49:39 #46279   VacuumLog:	p_ch=54800000.00/15 mPa,T_ch=29.8 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:49:42 #46279   VacuumLog:	p_ch=54800000.00/15 mPa,T_ch=29.8 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:49:46 #46279   VacuumLog:	p_ch=54800000.00/15 mPa,T_ch=30.0 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:49:50 #46279   VacuumLog:	p_ch=54800000.00/15 mPa,T_ch=29.9 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:49:53 #46279   VacuumLog:	p_ch=54800000.00/15 mPa,T_ch=29.9 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:49:55 #46279   Trigger:	Going through ..             
16:49:55 #46279   HWTrigger:	Going through ..             
16:49:55 #46279   HWTrigger:	Going with trigger Tch3 - TBt 0               
16:49:55 #46279   HWTrigger:	Going with trigger Tch4 - Tcd 1000               
16:49:57 #46279   VacuumLog:	p_ch=54800000.00/15 mPa,T_ch=30.0 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:49:58 #46279   SecurePostDischargeState:	Going through ..             
16:49:58 #46279   Relay:	#2@PowerSupplies  (PowerSupplyHVcontactor@PowerSupplies) goes OFF ..                
16:49:58 #46279   Relay:	#4@Miscellaneous  (Preionization-Engage@Miscellaneous) goes OFF ..                
16:49:58 #46279   Relay:	#2@Miscellaneous  (Preionization-Heater@Miscellaneous) goes OFF ..                
16:49:58 #46279   Relay:	#1@Miscellaneous  (Engage12V_24V_intosystem@Miscellaneous) goes OFF ..                
16:49:58 #46279   Relay:	#3@PowerSupplies  (ShortCircuits@PowerSupplies) goes OFF ..                
16:49:58 #46279   Relay:	#1@Miscellaneous  (Engage12V_24V_intosystem@Miscellaneous) goes OFF ..                
16:49:58 #46279   Relay:	#1@Vacuum  (Majak@Vacuum) goes OFF ..                
16:49:58 #46279   Relay:	#7@MiscII  (SignalTowerOrangeGreen@MiscII) goes OFF ..                
16:49:58 #46279   Relay:	#3@Miscellaneous  (Preionization-Shortcut@Miscellaneous) goes OFF ..                
16:49:58 #46279   Relay:	#8@MiscII  (SignalTowerRed@MiscII) goes OFF ..                
16:49:59 #46279   Relay:	#2@PowerSupplies  (PowerSupplyHVcontactor@PowerSupplies) goes OFF ..                
16:49:59 #46279   ChargingResistorsAllON:	Diving into ..             
16:50:01 #46279   Relay:	#3@PowerSupplies  (ShortCircuits@PowerSupplies) goes OFF ..                
16:50:01 #46279   VacuumLog:	p_ch=54800000.00/15 mPa,T_ch=29.8 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:50:02 #46279   Relay:	#12@Vacuum  (H2-pipe@Vacuum) goes OFF ..                
16:50:02 #46279   Relay:	#13@Vacuum  (He-pipe@Vacuum) goes OFF ..                
16:50:02 #46279   Relay:	#12@Vacuum  (H2-pipe@Vacuum) goes OFF ..                
16:50:02 #46279   Relay:	#13@Vacuum  (He-pipe@Vacuum) goes OFF ..                
16:50:05 #46279   VacuumLog:	p_ch=54800000.00/15 mPa,T_ch=29.9 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:50:07 #46279   SecurePostDischargeState:	Going through ..             
16:50:08 #46279   VacuumLog:	p_ch=54800000.00/15 mPa,T_ch=30.0 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:50:12 #46279   VacuumLog:	p_ch=54800000.00/15 mPa,T_ch=30.0 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:50:16 #46279   VacuumLog:	p_ch=54800000.00/15 mPa,T_ch=29.8 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:50:19 #46279   VacuumLog:	p_ch=54800000.00/15 mPa,T_ch=29.9 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:50:23 #46279   VacuumLog:	p_ch=54800000.00/15 mPa,T_ch=29.9 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:50:27 #46279   VacuumLog:	p_ch=54800000.00/15 mPa,T_ch=29.9 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:50:30 #46279   VacuumLog:	p_ch=54800000.00/15 mPa,T_ch=30.0 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:50:34 #46279   VacuumLog:	p_ch=54800000.00/15 mPa,T_ch=30.0 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:50:38 #46279   VacuumLog:	p_ch=54800000.00/15 mPa,T_ch=30.0 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:50:41 #46279   VacuumLog:	p_ch=54800000.00/15 mPa,T_ch=30.0 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:50:45 #46279   VacuumLog:	p_ch=54800000.00/15 mPa,T_ch=30.0 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:50:49 #46279   VacuumLog:	p_ch=54800000.00/15 mPa,T_ch=29.9 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:50:52 #46279   Relay:	#12@PositionStabilization  (MainSwitch4PositionStabilization) goes OFF ..                
16:50:52 #46279   VacuumLog:	p_ch=54800000.00/15 mPa,T_ch=30.0 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:50:56 #46279   VacuumLog:	p_ch=54700000.00/15 mPa,T_ch=30.0 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V               
16:51:00 #46279   VacuumLog:	p_ch=54700000.00/15 mPa,T_ch=29.9 C,p_fv=3000.0 Pa,Gas: NULL,U_wg=0.0 V