Golem shot: 4632

2011-02-24 - 125315

Basic parameters:
  • Chamber pressure pchamber : 2.38->19.66 mPa (request: 20 mPa)
  • Chamber temperature: 0 grad C
  • CBt capacitors (23 mF) charged to: 1200 V
  • CBD capacitors (3.6 mF) charged to: 200 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 7883 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.09 over 8.18 to 17.27 [ms]
  • Mean toroidal magnetic field Bt: 0.313 T
  • Mean plasma current: 1.4 kA
  • Mean Uloop: 8.1 V
  • Break down voltage: 6.4 V
  • Plasma total charge: 11.7 C
  • Ohmic heating power: 11.3 kW
  • Q edge: 20.2
  • Central electron temperature: 27.9 eV

Diagnostics: (configuration)

MirnovCoils_JK

FastCameraExilim

Analysis:

SafetyFactor_JK

Thanks to the specific help and