Golem shot: 4641

2011-02-24 - 164054

Basic parameters:
  • Chamber pressure pchamber : 2.02->18.49 mPa (request: 20 mPa)
  • Chamber temperature: 0 grad C
  • CBt capacitors (23 mF) charged to: 900 V
  • CBD capacitors (3.6 mF) charged to: 200 V, triggered 4,5 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 1128 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.5 over 6.98 to 16.48 [ms]
  • Mean toroidal magnetic field Bt: 0.233 T
  • Mean plasma current: 1.2 kA
  • Mean Uloop: 8.3 V
  • Break down voltage: 8.2 V
  • Plasma total charge: 8.2 C
  • Ohmic heating power: 10.0 kW
  • Q edge: 17.5
  • Central electron temperature: 24.7 eV

Diagnostics: (configuration)

MirnovCoils_JK

FastCameraExilim

Analysis:

SafetyFactor_JK