Golem shot: 4723

2011-03-03 - 201854

Basic parameters:
  • Chamber pressure pchamber : 6.66->6.58 mPa (vacuum shot)
  • Chamber temperature: 19 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 0 V, triggered 2,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 3542 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.98 over 3.81 to 12.79 [ms]
  • Mean toroidal magnetic field Bt: 0.133 T
  • Mean plasma current: 1.5 kA
  • Mean Uloop: 4.8 V
  • Break down voltage: 6.8 V
  • Plasma total charge: 5.9 C
  • Ohmic heating power: 7.2 kW
  • Q edge: 8.0
  • Central electron temperature: 41.4 eV

Diagnostics: (configuration)

MirnovCoils_JK

FastCameraExilim

Analysis:

SafetyFactor_JK

Thanks to the specific help and