Golem shot: 4726

2011-03-03 - 203030

Basic parameters:
  • Chamber pressure pchamber : 5.73->34.43 mPa (request: 30 mPa)
  • Chamber temperature: 18 grad C
  • CBt capacitors (23 mF) charged to: 1400 V
  • CBD capacitors (3.6 mF) charged to: 0 V, triggered 2,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 4284 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 10.09 over 9.32 to 19.41 [ms]
  • Mean toroidal magnetic field Bt: 0.380 T
  • Mean plasma current: 1.7 kA
  • Mean Uloop: 5.6 V
  • Break down voltage: 7.2 V
  • Plasma total charge: 15.6 C
  • Ohmic heating power: 9.5 kW
  • Q edge: 20.2
  • Central electron temperature: 40.6 eV

Diagnostics: (configuration)

MirnovCoils_JK

FastCameraExilim

Analysis:

SafetyFactor_JK

Thanks to the specific help and