Automatic mode activated.
Input configuration: Setting.json
Output configuration: SettingOut.json
Shot number is: 0
List of active spectrometers from JSON (5):
 0 HR+C1886 alias IRVISUV
 1 HR+C1834 alias Halpha
 2 HR+C0732 alias VIS
 3 HR+C2729 alias IR
 4 HR2+C1103 alias UV
Connected to spectrometer [0]
 Spectrometer[0] model: HR2000PLUS
 Spectrometer[0] serial number: HR2+C1103
Connected to spectrometer [1]
 Spectrometer[1] model: HR2000PLUS
 Spectrometer[1] serial number: HR+C1834
Connected to spectrometer [2]
 Spectrometer[2] model: HR2000PLUS
 Spectrometer[2] serial number: HR+C0732
Connected to spectrometer [3]
 Spectrometer[3] model: HR2000PLUS
 Spectrometer[3] serial number: HR+C2729
Connected to spectrometer [4]
 Spectrometer[4] model: HR2000PLUS
 Spectrometer[4] serial number: HR+C1886
Setting spectrometer HR+C1886 (IRVISUV)
 Firmware: 12344
 High Delay is 0 (set is 0), Low Delay is 1000 (set is 1000)
 Spectrometer strobe is enabled
 Setting integration time:
   Trigger mode is Software (0)
   Integration time is 2000 us
   Spectrum length is 2048
   Specta count is 20
   Spectrum was acquired to set spectrometer
   Trigger mode is Hardware
 Done
Setting spectrometer HR+C1834 (Halpha)
 Firmware: 12344
 High Delay is 0 (set is 0), Low Delay is 1000 (set is 1000)
 Spectrometer strobe is enabled
 Setting integration time:
   Trigger mode is Software (0)
   Integration time is 2000 us
   Spectrum length is 2048
   Specta count is 20
   Spectrum was acquired to set spectrometer
   Trigger mode is Hardware
 Done
Setting spectrometer HR+C0732 (VIS)
 Firmware: 12345
 High Delay is 0 (set is 0), Low Delay is 1000 (set is 1000)
 Spectrometer strobe is enabled
 Setting integration time:
   Trigger mode is Software (0)
   Integration time is 2000 us
   Spectrum length is 2048
   Specta count is 20
   Spectrum was acquired to set spectrometer
   Trigger mode is Hardware
 Done
Setting spectrometer HR+C2729 (IR)
 Firmware: 12345
 High Delay is 0 (set is 0), Low Delay is 1000 (set is 1000)
 Spectrometer strobe is enabled
 Setting integration time:
   Trigger mode is Software (0)
   Integration time is 2000 us
   Spectrum length is 2048
   Specta count is 20
   Spectrum was acquired to set spectrometer
   Trigger mode is Hardware
 Done
Setting spectrometer HR2+C1103 (UV)
 Firmware: 12345
 High Delay is 0 (set is 0), Low Delay is 1000 (set is 1000)
 Spectrometer strobe is enabled
 Setting integration time:
   Trigger mode is Software (0)
   Integration time is 2000 us
   Spectrum length is 2048
   Specta count is 20
   Spectrum was acquired to set spectrometer
   Trigger mode is Hardware
 Done
Collecting spectra
Acquisition statistic for spectrometer HR+C1886 (IRVISUV)
 Temperature: 30.623 °C
 Average time: 1.9969 ms
 Delay relative to the first finished spectrometer: 0 ms
Acquisition statistic for spectrometer HR+C1834 (Halpha)
 Temperature: 30.6855 °C
 Average time: 1.9942 ms
 Delay relative to the first finished spectrometer: 0.000435 ms
Acquisition statistic for spectrometer HR+C0732 (VIS)
 Temperature: 30.748 °C
 Average time: 1.99583 ms
 Delay relative to the first finished spectrometer: 1.4e-05 ms
Acquisition statistic for spectrometer HR+C2729 (IR)
 Temperature: 29.4981 °C
 Average time: 1.99205 ms
 Delay relative to the first finished spectrometer: 0.116942 ms
Acquisition statistic for spectrometer HR2+C1103 (UV)
 Temperature: 30.1856 °C
 Average time: 1.99414 ms
 Delay relative to the first finished spectrometer: 0.009032 ms
Saving output configuration JSON to SettingOut.json