Golem shot: 4733

2011-03-07 - 153715

Basic parameters:
  • Chamber pressure pchamber : 3.15->19.96 mPa (request: 20 mPa)
  • Chamber temperature: 25 grad C
  • CBt capacitors (23 mF) charged to: 800 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 1881 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.01 over 8.98 to 17.99 [ms]
  • Mean toroidal magnetic field Bt: 0.197 T
  • Mean plasma current: 2.0 kA
  • Mean Uloop: 5.3 V
  • Break down voltage: 6.8 V
  • Plasma total charge: 18.3 C
  • Ohmic heating power: 10.6 kW
  • Q edge: 8.9
  • Central electron temperature: 46.9 eV

Diagnostics: (configuration)

MirnovCoils_JK

FastCameraExilim

Analysis:

SafetyFactor_JK

Thanks to the specific help and