Golem shot: 4734

2011-03-07 - 154204

Basic parameters:
  • Chamber pressure pchamber : 3.15->21.64 mPa (request: 20 mPa)
  • Chamber temperature: 25 grad C
  • CBt capacitors (23 mF) charged to: 800 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 2189 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.33 over 10.22 to 18.55 [ms]
  • Mean toroidal magnetic field Bt: 0.192 T
  • Mean plasma current: 3.4 kA
  • Mean Uloop: 7.6 V
  • Break down voltage: 9.0 V
  • Plasma total charge: 34.6 C
  • Ohmic heating power: 25.8 kW
  • Q edge: 5.1
  • Central electron temperature: 52.5 eV

Diagnostics: (configuration)

MirnovCoils_JK

FastCameraExilim

Analysis:

SafetyFactor_JK

Thanks to the specific help and