Golem shot: 4750

2011-03-10 - 130731

Basic parameters:
  • Chamber pressure pchamber : 2.76->21.47 mPa (request: 20 mPa)
  • Chamber temperature: 48 grad C
  • CBt capacitors (23 mF) charged to: 800 V
  • CBD capacitors (3.6 mF) charged to: 200 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 2708 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.14 over 2.18 to 10.32 [ms]
  • Mean toroidal magnetic field Bt: 0.140 T
  • Mean plasma current: 1.4 kA
  • Mean Uloop: 9.9 V
  • Break down voltage: 11.2 V
  • Plasma total charge: 3.1 C
  • Ohmic heating power: 13.9 kW
  • Q edge: 9.0
  • Central electron temperature: 24.4 eV

Diagnostics: (configuration)

MirnovCoils_JK

FastCameraExilim

Analysis:

SafetyFactor_JK

Thanks to the specific help and