Automatic mode activated. Input configuration: Setting.json Output configuration: SettingOut.json Shot number is: 0 List of active spectrometers from JSON (5): 0 HR+C1886 alias IRVISUV 1 HR+C1834 alias Halpha 2 HR+C0732 alias VIS 3 HR+C2729 alias IR 4 HR2+C1103 alias UV Connected to spectrometer [0] Spectrometer[0] model: HR2000PLUS Spectrometer[0] serial number: HR2+C1103 Connected to spectrometer [1] Spectrometer[1] model: HR2000PLUS Spectrometer[1] serial number: HR+C1834 Connected to spectrometer [2] Spectrometer[2] model: HR2000PLUS Spectrometer[2] serial number: HR+C0732 Connected to spectrometer [3] Spectrometer[3] model: HR2000PLUS Spectrometer[3] serial number: HR+C2729 Connected to spectrometer [4] Spectrometer[4] model: HR2000PLUS Spectrometer[4] serial number: HR+C1886 Setting spectrometer HR+C1886 (IRVISUV) Firmware: 12344 High Delay is 0 (set is 0), Low Delay is 1000 (set is 1000) Spectrometer strobe is enabled Setting integration time: Trigger mode is Software (0) Integration time is 2000 us Spectrum length is 2048 Specta count is 20 Spectrum was acquired to set spectrometer Trigger mode is Hardware Done Setting spectrometer HR+C1834 (Halpha) Firmware: 12344 High Delay is 0 (set is 0), Low Delay is 1000 (set is 1000) Spectrometer strobe is enabled Setting integration time: Trigger mode is Software (0) Integration time is 2000 us Spectrum length is 2048 Specta count is 20 Spectrum was acquired to set spectrometer Trigger mode is Hardware Done Setting spectrometer HR+C0732 (VIS) Firmware: 12345 High Delay is 0 (set is 0), Low Delay is 1000 (set is 1000) Spectrometer strobe is enabled Setting integration time: Trigger mode is Software (0) Integration time is 2000 us Spectrum length is 2048 Specta count is 20 Spectrum was acquired to set spectrometer Trigger mode is Hardware Done Setting spectrometer HR+C2729 (IR) Firmware: 12345 High Delay is 0 (set is 0), Low Delay is 1000 (set is 1000) Spectrometer strobe is enabled Setting integration time: Trigger mode is Software (0) Integration time is 2000 us Spectrum length is 2048 Specta count is 20 Spectrum was acquired to set spectrometer Trigger mode is Hardware Done Setting spectrometer HR2+C1103 (UV) Firmware: 12345 High Delay is 0 (set is 0), Low Delay is 1000 (set is 1000) Spectrometer strobe is enabled Setting integration time: Trigger mode is Software (0) Integration time is 2000 us Spectrum length is 2048 Specta count is 20 Spectrum was acquired to set spectrometer Trigger mode is Hardware Done Collecting spectra Acquisition statistic for spectrometer HR+C1886 (IRVISUV) Temperature: 32.3729 °C Average time: 1.99415 ms Delay relative to the first finished spectrometer: 0 ms Acquisition statistic for spectrometer HR+C1834 (Halpha) Temperature: 32.4979 °C Average time: 1.99726 ms Delay relative to the first finished spectrometer: -0.053922 ms Acquisition statistic for spectrometer HR+C0732 (VIS) Temperature: 32.4979 °C Average time: 1.99989 ms Delay relative to the first finished spectrometer: -0.038187 ms Acquisition statistic for spectrometer HR+C2729 (IR) Temperature: 31.1855 °C Average time: 2.00003 ms Delay relative to the first finished spectrometer: -0.037646 ms Acquisition statistic for spectrometer HR2+C1103 (UV) Temperature: 31.9355 °C Average time: 1.9952 ms Delay relative to the first finished spectrometer: -0.053782 ms Saving output configuration JSON to SettingOut.json