Golem shot: 4778

2011-03-10 - 152315

Basic parameters:
  • Chamber pressure pchamber : 2.61->21.06 mPa (request: 20 mPa)
  • Chamber temperature: 45 grad C
  • CBt capacitors (23 mF) charged to: 1200 V
  • CBD capacitors (3.6 mF) charged to: 250 V, triggered 5,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 550 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 10871 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.26 over 10.8 to 20.06 [ms]
  • Mean toroidal magnetic field Bt: 0.320 T
  • Mean plasma current: 3.2 kA
  • Mean Uloop: 9.1 V
  • Break down voltage: 10.3 V
  • Plasma total charge: 34.6 C
  • Ohmic heating power: 29.1 kW
  • Q edge: 9.0
  • Central electron temperature: 44.7 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

FastCameraExilim

Analysis:

SafetyFactor_JK

Thanks to the specific help and