Golem shot: 4780

2011-03-10 - 152826

Basic parameters:
  • Chamber pressure pchamber : 2.68->20.82 mPa (request: 20 mPa)
  • Chamber temperature: 45 grad C
  • CBt capacitors (23 mF) charged to: 800 V
  • CBD capacitors (3.6 mF) charged to: 150 V, triggered 5,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 350 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 11161 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 10.05 over 9.33 to 19.38 [ms]
  • Mean toroidal magnetic field Bt: 0.219 T
  • Mean plasma current: 1.7 kA
  • Mean Uloop: 6.0 V
  • Break down voltage: 7.9 V
  • Plasma total charge: 16.1 C
  • Ohmic heating power: 10.2 kW
  • Q edge: 11.6
  • Central electron temperature: 38.7 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

FastCameraExilim

Analysis:

SafetyFactor_JK

Thanks to the specific help and