Golem shot: 4804

2011-03-10 - 162955

Basic parameters:
  • Chamber pressure pchamber : 2.63->19.96 mPa (request: 20 mPa)
  • Chamber temperature: 46 grad C
  • CBt capacitors (23 mF) charged to: 1200 V
  • CBD capacitors (3.6 mF) charged to: 200 V, triggered 5,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 550 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 14874 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.3 over 11.24 to 20.54 [ms]
  • Mean toroidal magnetic field Bt: 0.320 T
  • Mean plasma current: 2.7 kA
  • Mean Uloop: 9.3 V
  • Break down voltage: 10.5 V
  • Plasma total charge: 29.9 C
  • Ohmic heating power: 25.1 kW
  • Q edge: 10.7
  • Central electron temperature: 39.4 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

FastCameraExilim

Analysis:

SafetyFactor_JK

Thanks to the specific help and