Golem shot: 4809

2011-03-10 - 164408

Basic parameters:
  • Chamber pressure pchamber : 2.62->20.66 mPa (request: 20 mPa)
  • Chamber temperature: 46 grad C
  • CBt capacitors (23 mF) charged to: 1600 V
  • CBD capacitors (3.6 mF) charged to: 220 V, triggered 5,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 550 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 15759 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.26 over 11.35 to 20.61 [ms]
  • Mean toroidal magnetic field Bt: 0.432 T
  • Mean plasma current: 2.6 kA
  • Mean Uloop: 9.4 V
  • Break down voltage: 10.3 V
  • Plasma total charge: 29.4 C
  • Ohmic heating power: 24.4 kW
  • Q edge: 15.0
  • Central electron temperature: 38.1 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

FastCameraExilim

Analysis:

SafetyFactor_JK