Golem shot: 4815

2011-03-10 - 182416

Basic parameters:
  • Chamber pressure pchamber : 2.49->21.06 mPa (request: 20 mPa)
  • Chamber temperature: 173 grad C
  • CBt capacitors (23 mF) charged to: 1400 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 2437 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.89 over 16.04 to 24.93 [ms]
  • Mean toroidal magnetic field Bt: 0.351 T
  • Mean plasma current: 3.6 kA
  • Mean Uloop: 4.3 V
  • Break down voltage: 8.9 V
  • Plasma total charge: 57.7 C
  • Ohmic heating power: 15.5 kW
  • Q edge: 8.8
  • Central electron temperature: 79.8 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

FastCameraExilim

Analysis:

SafetyFactor_JK

Thanks to the specific help and