Golem shot: 4820

2011-03-10 - 191557

Basic parameters:
  • Chamber pressure pchamber : 2.33->20.12 mPa (request: 20 mPa)
  • Chamber temperature: 0 grad C
  • CBt capacitors (23 mF) charged to: 1400 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 0,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 5538 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 6.94 over 16.73 to 23.67 [ms]
  • Mean toroidal magnetic field Bt: 0.347 T
  • Mean plasma current: 4.0 kA
  • Mean Uloop: 4.1 V
  • Break down voltage: 8.8 V
  • Plasma total charge: 66.2 C
  • Ohmic heating power: 16.4 kW
  • Q edge: 7.8
  • Central electron temperature: 88.3 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

FastCameraExilim

Analysis:

SafetyFactor_JK

Thanks to the specific help and