Golem shot: 4830

2011-03-10 - 195930

Basic parameters:
  • Chamber pressure pchamber : 2.36->21.89 mPa (request: 20 mPa)
  • Chamber temperature: 0 grad C
  • CBt capacitors (23 mF) charged to: 1400 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 0,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 8154 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 6.77 over 17.23 to 24 [ms]
  • Mean toroidal magnetic field Bt: 0.335 T
  • Mean plasma current: 4.6 kA
  • Mean Uloop: 4.8 V
  • Break down voltage: 10.5 V
  • Plasma total charge: 78.9 C
  • Ohmic heating power: 22.1 kW
  • Q edge: 6.6
  • Central electron temperature: 87.3 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

FastCameraExilim

Analysis:

SafetyFactor_JK

Thanks to the specific help and