Golem shot: 4857

2011-03-22 - 121954

Basic parameters:
  • Chamber pressure pchamber : 2.40->19.14 mPa (request: 20 mPa)
  • Chamber temperature: 195 grad C
  • CBt capacitors (23 mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 2,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 15425 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.16 over 5.82 to 14.98 [ms]
  • Mean toroidal magnetic field Bt: 0.204 T
  • Mean plasma current: 1.2 kA
  • Mean Uloop: 7.8 V
  • Break down voltage: 10.1 V
  • Plasma total charge: 6.8 C
  • Ohmic heating power: 9.4 kW
  • Q edge: 15.4
  • Central electron temperature: 25.8 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and